Справочник Пользователя для Barco k5960012-04

Скачать
Страница из 262
172    Barco - RHDM-2301 - User manual   
Addendum
7.1.1.2  Image specifications
7.1.1.2.1
Response time
•  Typical rise time: 6 ms
•  Typical fall time: 6 ms
7.1.1.2.2
Tolerances
Tolerance test colors
The display unit complies with the following tolerances for the test colors specified in the EBU Tech
3325:
Maximal: 
Typical:  
In the table below, the Luminance Y is expressed in %. 100% is reference white.
Test color
Description
Y (%)
u’
v’
EBU 1
Dark Skin
9.6
0
.
253
0
.5015
EBU 2
Light Skin
37.7
0
.
2366
0
.
4931
EBU 3
Light Greyish Red
29.8
0
.
2364
0
.
4848
EBU 4
Light Yellow Green
29
.
9
0
.
1807
0
.
5452
EBU 5
Light Bluish Green
29.8
0
.
1629
0
.
4552
EBU 6
Light Violet
30.1
0
.
2087
0
.
4157
EBU 7
Foliage
13
.
4
0
.
1813
0
.
5207
EBU 8
Medium Red
19.4
0
.
3248
0
.
4974
EBU 9
Medium Green
43
.
6
0
.
1505
0
.
5329
EBU 10
Medium Blue
17.2
0
.
1791
0
.
3706
0045
.
0
'
'
∆ v
u
0015
.
0
'
'
∆ v
u