C2472M-A (12/05)
SW1
SW2
SW3
1  2  3  4
 
5
 
6
 
7
 
8
1  2  3  4
 
5
 
6
 
7
 
8
1   
on
on
ON
SW1-1 is set to the ON position.
All other switches are set to the OFF position.
Figure 1.  Default Switch Settings
WELCOME
Thank you for purchasing Pelco’s Spectra III
 SE/Spectra III
 Series dome system. This manual provides the information required to
set up and install the dome drive. Please thoroughly familiarize yourself with the information in this manual before attempting
installation.
NOTE:  This manual does not contain instructions for installing a complete Spectra III SE/Spectra III Series system. For complete
instructions refer to the installation packet shipped with the back box.
SETUP FOR COAXITRON PROTOCOL
No DIP switch settings are required for Coaxitron control. Proceed to 
Dome Drive Installation on page 4.
SETUP FOR D AND P SERIES PROTOCOL
PROTOCOL SETTINGS
The Spectra III SE and Spectra III Series dome drives automatically detect type of protocol. No switch settings are required to set
Coaxitron
®
, RS-422 P and D Series protocols.
SWITCH SETTINGS
NOTE:  If you have a Spectra III EVS dome system, make sure the
switches are in their default positions (refer to Figure 1). The
switches configure the dome for address 1 (D-type control),
2400 baud, and no termination. Proceed to 
Dome Drive Installation
on page 4.
Before installing the dome drive, configure the receiver address,
termination, and baud setting. The DIP switches, to configure these
settings, are located on the side of the dome drive.
Figure 1 shows the default settings for the DIP switches. Switch SW1-1 (SW1, switch 1) is set to the ON position. All other switches
are set to the OFF position.
Refer to the following sections to set the address, termination, and baud setting for the dome drive.
SW1–Receiver Address
Set the SW1 switches for the address of the dome drive. The following information is required to set the dome drive address:
P-Type Control
Default address is 2. Refer to Table A for address settings that use P-Type control. Maximum number of
receivers is 32.
D-Type Control
Default address is 1. Refer to Table B for address settings that use D-Type control. Maximum number of
receivers is 254.
NOTE:  Coaxitron Control - No address settings are required.