Справочник Пользователя для Bush Hog 300

Скачать
Страница из 62
OPERATION
300 Series   09/10
Operation Section 4-25
© 2010 Alamo Group Inc.
OPERA
T
ION
Problem
Possible Cause
Remedy
Hydraulic Pump not shutting
Using Open Center Valve
Replace Valve or Conversion Plug
off on Closed Center System
and Main Relief
Open Center Conversion Plug
Replace with Closed Center Plug
Pumping over Relief Valve
Replace with No Relief Plug
Oil leaking at hose
Connection not tight
Tighten connection
connection
Did not use sealant
Apply a good sealant to connection
Connection cracked from
Replace cracked connection
over-tightening
Mismatched Connection threads
Use correct connectors
or types.