Figure 2-6
J.  Secure  hydraulic  hoses  to  tractor  to  prevent
interference.  It  is  recommended  that  hoses  be  rout-
ed under tractor operator’s platform.
K.  Extend  and  retract  both  sets  of  cylinders
beginning with short strokes. Gradually increase the
length  of  stroke  until  cylinders  “bottom  out”  in  each
direction.  Hold  valve  open  with  cylinders  “bottomed
out”  for  3-5  seconds.  This  will  purge  air  from
hydraulic components.
NOTE
When valve  control is held open, a squealing noise
will  be  heard  when  cylinders  ”bottom  out”  and
hydraulic  oil  passes  through  relief  valve.  This  may
cause  overheating  if  valve  control  is  held  open
longer than 5 seconds.
Make  certain  optional  control  valve  operates  as
shown on decal . If valve operation is incorrect, see
plumbing diagrams for correct connections.
12
Cylinder Mounting Bushing
AIR IN HYDRAULIC COMPONENTS WILL
CAUSE  ERRATIC  LOADER  OPERATION.
PURGE  AIR  FROM  SYSTEM  AS
DESCRIBED ABOVE BEFORE WORKING
WITH  LOADER.  FAIULURE  TO  DO  SO
CAN  RESULT  IN  PERSONAL  INJURY
AND EQUIPMENT DAMAGE.
2-3 DISMOUNTING LOADER
Dismount  loader  on  firm,  level  ground  to  facilitate
the next mounting. It is recommended that loader be
stored in a dry place to prevent rusting.
A. Observe the position of boom cylinder mount-
ing bushing in relation to the subframe. (Figure 2-6)
Remember this position to aid in aligning cross tube
with  front  bracket  when  loader  is  being  mounted  to
tractor.
B.  Remove  parking  stands  from  storage.  Raise
boom and install as shown in Figure 2-7.
Figure 2-7  Parking Stands Installed
CAUTION