page 26 —gb12bw/bs/bp LIgHTINg sYsTeM • operaTIoN aNd parTs MaNuaL — rev. #0 (06/24/13) 
oPeration (Gb12bs)
raIsINg THe MasT (gb12bs)
1.  Before raising the mast, make sure the T-handle bolt 
lock is securely tightened. This will prevent the balloon/
lamp assembly from falling off. 
2.  Raise extension pole to desired height. Watch out for 
any overhead obstructions.
3.  Tighten extension clamp bolt securely. 
  daNger
ALWAYS make sure 
the area above the 
lighting system is open 
and clear of overhead 
power lines  and other 
obstructions. The mast 
extends in excess of 
13 ft. (4 meters) when 
an optional extension 
is used. Contact with 
overhead power lines 
or other obstructions 
could result in equipment 
damage,  serious Injury 
or death!
  daNger
When raising mast, 
ALWAYS 
be on the lookout for overhead 
obstructions such as high voltage 
power lines. The possibility exists 
of electrocution, even death if the 
lighting system comes in contact 
with high voltage power lines.
appLYINg power (gb12bs)
1.  If using a portable generator, start the generator as 
referenced in the "Start-up Section" of the supplied 
generator manual.
2.  Once the generator has started, plug the AC power 
cord from the lamp into a GFCI receptacle on the 
generator.
3.  If using a power source (Figure 34) other than a 
portable generator, plug the  AC power cord from the 
lamp into a 120 VAC, 60 Hz receptacle that is protected 
by a at least a 15 amp circuit breaker.
Figure 34. 120 VAC Receptacle
EXTERNAL
SINGLE-PHASE
(120 VAC)
POWER SOURCE
POWER CABLE
RECEPTACLE
 NOTICE
Refer to previous sections on Applying Power 
(GB12BW), Dimming the Lamp, and Shutdown for 
procedures in operating the lamp.