Справочник Пользователя для Radware VOYA-GRAND-MBK

Скачать
Страница из 56
Page  14
7075-166
September 25, 2012
R
VOYAGEUR GRAND Wood Insert
O.  Blower Operating Instructions
1. 
Initial (cold) startup:  
Open both controls fully by rais-
ing the Burn Rate Air Control all the way up until it stops
and  PUSH  the  Start-up Air  Control  back  until  it  stops.
The blower tends to cool the appliance. Leave the blower
off until the burn is well established, i.e., 30 minutes.
2
. High Burn Setting:  Both controls are open.  Burn Rate 
Air Control is pulled up and the Start-up Air Control is
fully pushed in.  Blower may remain on.
3. 
Medium-High  Burn  Setting*:    Burn  Rate Air  Control
is closed then opened to 1 inch to fully open (pull up).  
Blower may remain on.
4. 
Medium-Low  Burn  Setting*:    Burn  Rate  Air  Control
is closed then opened to 1/4 inch to 1/2 inch (pull up).
Leave the blower off until the burn is well established, i.e., 
30 minutes.
5. 
Low  Burn  Setting*:    Burn  Rate Air  Control  is  closed
(down position).  Leave the blower off until the burn is 
well established, i.e., 30 minutes.
*NOTE: For burn settings 3 to 5 the Start-up Air Control
needs  to  be  pushed  in  (Open)  then  pulled  forward  to
activate the Automatic Combustion Control (ACC).
NOTE:  For maximum efficiency and lowest emissions,
when operating the blower in either the automatic or 
manual setting for the low and medium low burn settings 
leave the blower off until the burn is well established, i.e., 
30 minutes.
6.  The blower is equipped with a rheostat (speed control).
The  highest  blower  speed  is  obtained  by  turning  the
rheostat on, then adjusting back towards “OFF” as far
as  possible  without  turning  the  blower  off.    For  a  low
blower speed, turn the control knob clockwise as far as
possible
Blower Controls Under Ash Lip
MANUAL:  over-
rides the internal 
snap disc
AUTO:  Fan with turn ON/OFF 
automatically and is controlled 
by the internal Snap Disc
1.  The  blower  will  turn  on/off  automatically  when  set  to
AUTO.
Figure 14.1.
2.  When set to MANUAL, the fan will turn on/off only when
you turn it on or off. This setting over-rides the internal
snap disc.
3.  Swing  the  grille  downward  to  expose  the  blower  con-
trols. Adjust the speed of the fan by turning the HIGH/
LOW knob to the desired setting.
N.  Blower Control Box & Snap Disc
Operating Instructions
Figure 15.1
NOTICE!
Do NOT operate a circulating fan within close proxim-
ity, approximately 4 ft (1.2m), of appliance
 • Can reverse air flow, blowing hot air into appliance
cavity.
 • Can damage appliance blower due to overheating.