VOYAGEUR GRAND Wood Insert
10 ft. (305cm) or more
3 ft. (91cm) Minimum
Less than 10 ft. (305cm)
2 ft. (61cm) Minimum
3 ft. (91cm) Minimum
Wall or Parapet
Flat Roof
3 ft.  (91cm)
Minimum
Less than 10 ft. (305cm) 
2 ft. (61cm)  
3 ft. (91cm)  
Minimum 
10 ft. (305cm) To Nearest Roofline 
2 ft. (61cm) 
Pitched Roof
These are safety requirements and are not meant to assure proper flue draft.
Figure 28.1
F.  2-10-3 Rule
Figure 28.2
This appliance is made with a 6 inch (152mm) diameter chimney connector as the flue collar on the unit.
•  Changing the diameter of the chimney can affect draft and cause poor performance.
•  It is not recommended to use offsets and elbows at altitudes above 4000 feet above sea level and or when
there are other factors that affect flue draft.