VOYAGEUR GRAND Wood Insert
R
UL 1777 Insulated Stainless Steel 
Liner or Other Approved Lining System 
Follow Manufacturer’s Instructions 
on Insulation and Support 
For Zero or Other Non-Code Clearances, 
Follow Approved Liner Manufacturer’s Specific 
Insulation Requirements:  Different Clearances 
May Require Different Specifications 
Masonry Chimney Must 
Have Structural Integrity 
UL 1777 Insulated Stainless Steel 
Liner or Other Approved Lining System 
Minimum 8 in. (203mm) Masonry 
Thickness in Front of Smoke Chamber
Damper Plate Removed or 
Fastened in Open Position 
Seal with Non-Combustible Material 
Minimum Clearance in Accordance 
with Insert Listing 
Floor Protection in 
Accordance with Insert 
Listing 
Follow Manufacturer’s 
Instructions for Maximum 
Liner Extension Above 
Chimney 
Maximum 30
 
Degrees 
Offset in Chimney 
Combustible Floor 
Masonry Chimney (Cont’d)
Figure 35.1 - Masonry Chimney with a Full Liner Kit Type UL103HT Rquirement per UL1777
NOTE: In Canada, this fireplace insert must be installed
with a continuous chimney liner of a 6 inch (152mm) diam-
eter extending from the fireplace insert to the the top of the
chimney.  
The chimney liner must conform to the Class 3 require-
ments of CAN/ULC-S635, Standard for Lining Systems for
Existing  Masonry  or  Factory-Built  Chimneys  and  Vents,
or CAN/ULC-S640, Standard for Lining Systems for New
Masonry Chimneys.
This  insert  conforms  with  the  UL  1482  and  ULC  S628
(Canada)  in  all  respects,  and  is  approved  to  UL  &  ULC
safety standards for installation and use within a fireplace
with a masonry chimney in accordance with NFPA 211 and
CAN/CSA-B365-01.
NOTE:  Generic wood insert shown - not model specific
In USA a minimum 5 foot length, 6 inch diameter flue 
liner  is  required  as  per  UL  1482,  however  Hearth  & 
Home Technologies strongly recommends a full reline 