3. INSTALLATION
The boundary wire should not be laid across a slope 
that is steeper than 10 %. There is a risk of 
Automower finding it difficult to turn there. The mower 
will then stop and show the fault message Outside 
working area
. The risk is at its greatest in damp 
weather conditions, as the wheels can slip on the wet 
grass.
However, the boundary wire can be laid across a 
slope steeper than 10 % when there is an obstacle 
that Automower can be permitted to collide with, for 
example, a fence or a dense hedge.
Automower can mow areas inside 
the working area that slope up to 
35 cm per distance metre (35 %). 
Areas that slope more must be 
demarcated by the boundary wire.
When any part of the working area's 
boundary slopes more than 10 cm 
per distance metre (10 %), the 
boundary wire must be routed about 
35 cm in on flat ground before the 
slope starts.
Laying out the boundary wire
Run the boundary wire around the working area, but 
wait before connecting the wire to the charging 
station.