Справочник Пользователя для Cal Spas LTR20111058

Скачать
Страница из 32
2011 Genesis Portable Spa
LTR20111058, Rev. B
Pr
eparing f
or 
Your Ne
w P
or
tab
le Spa
www.calspas.com
4
110V / 60 Hz
This  product  is  a  cord-connected  spa  with  a  pump 
heater, lighting fixture, and spa side control. The op-
erating power is 110V AC.
A  licensed  electrician  may  be  required  to  upgrade 
your  standard  receptacle  and/or  circuit  breaker.  Al-
ways follow applicable local, state and federal codes 
and guidelines.
The spa is equipped with a 15 amp GFCI cord and 
plug kit.
Plug the spa into a dedicated electrical line with a 15 
amp breaker.
Always use a weatherproof-covered receptacle. Re-
ceptacle  shall  be  located  not  less  than  5  feet  (1.5 
m) from and not exceeding 10 feet (3.0 m) from the 
inside wall of the spa (NEC 680.43(A)).
Do not use extension cords. Using an extension cord 
will void your warranty.
Do not bury the power cord. If your cord becomes 
damaged, replace it before next usage.
If  you  need  to  replace  your  cord,  replace  it  with  a 
15 amp GFCI connection. The cord may not be lon-
ger than 15 feet (4.6 m). You can order a replace-
ment GFCI and cord kit from Cal Spas, part number 
ELE09700086.
Electrical Installation
Testing the GFCI
Test the GFCI plug prior to first use and periodically 
when the spa is powered.
Plug in the GFCI into the power outlet. The indi-
1. 
cator should turn on.
Press  the  TEST  button.  The  GFCI  will  trip,  the 
1. 
indicator will turn off, and the spa will stop op-
erating.
Press the RESET button. The GFCI will reset, the 
2. 
indicator will turn on again, and the spa will turn 
back on.
The spa is now safe to use.
If the GFCI trips while the spa is in use, press the 
RESET button. If the GFCI does not reset, unplug the 
spa and call your local Cal Spas dealer for service. DO 
NOT USE THE SPA!