Introduction
These instructions present general recommendations for
installation, operation and maintenance of vertical
induction motors built at the Norwood Plant.  If additional
information is required, contact Siemens Indust
ry
.
Warranty
See your sales contract for warranty coverage.
Documentation of storage maintenance, alignment and
regreasing may be required for certain warranty
considerations.
Receiving
Motors are shipped in first class condition.  They have
been inspected and are blocked or crated to prevent
damage from ordinary handling during shipment.
Inspect new motors for shipping damage when received.
Make the examination before removing from cars or
trucks.  If damage or indication of rough handling is
evident, file a claim with the carrier at once, and notify your
Siemens 
sales
 representative.
Remove only the shipping invoice.  Do not remove tags
pertaining to lubrication, operation, and storage
instructions.  Read and follow all instructions to insure that
no damage to motor bearings, (due to condensation) and
motor windings occurs during storage.
Use care in handling.  Dropping the motor or otherwise
imposing shock loads can cause unseen and undetected
damage to bearings.  This damage such as false brinelling
of the races of anti-friction bearings can result in early
bearing failure.
If supplied, energize space heaters to help prevent
condensation within the enclosure.
Motors having grease lubricated antifriction bearings are
shipped with the bearings already lubricated and ready for
operation.  
If the elapsed time from the time of shipment to the time in
which the unit is to be started is in excess of three (3)
months, three (3) ounces of grease specified on the
lubrication plate mounted on the motor should be added to
each bearing prior to the motor commissioning.
Motors having oil lubricated bearings are shipped
WITHOUT OIL in the bearing reservoir.  These bearings
and journal surfaces are protected during shipment by a
TEMPORARY film of rust inhibiting oil.
Immediately upon receiving a unit with oil lubricated
bearings:
1.
Check for moisture accumulation.  Remove any traces
of oxidation before putting the motor in service.
2.
Fill bearing reservoirs to normal level with a non-
foaming, non-detergent turbine oil (See Maintenance
page 11).
3.
Rotate the shaft several turns, by hand, to distribute
the oil over bearing parts.
1
Hazardous voltage.
Will cause death, serious injury,
electrocution or property damage.
Disconnect all power before working on
this equipment.