SPECIFICATIONS
GENERATOR
Type ............................................................................. Synchronous
Rotor Insulation ................................................................... Class H
Stator Insulation .................................................................. Class H
Total Harmonic Distortion ......................................................< 3.5%
Telephone Interference Factor (TIF) ..........................................< 50
Alternator Output Leads 3-phase ........................................... 4-wire
Bearings .........................................................................Sealed Ball
Coupling .......................................................................Flexible Disc
Load Capacity (Standby Rating) ............................................40kW*
*
  NOTE: Generator rating and perfomance in accordance with ISO8528-5, BS5514, SAE J1349, 
ISO3046 and DIN 6271 Standards. KW rating is based on LPG fuel and may derate with natural 
gas.
Excitation System ....................................................................Direct
Generator Output Voltage/kW - 60 Hz 
kW 
Amp  CB Size
  120/240V, 1-phase, 1.0 pf (LP) 
40 
167 
175
  120/240V, 1-phase, 1.0 pf (NG) 
37 
154 
175
Generator Locked Rotor KVA Available @ Voltage Dip of 35%
  Single-phase or 208 3-phase ............................................. 80 KVA
ENGINE
Make ................................................................................... Generac
Model ...................................................................................... V-type
Cylinders and Arrangement ............................................................ 6
Displacement ....................................................................... 3.9  Liter
Bore ...................................................................................... 3.91  in.
Stroke ................................................................................... 3.31  in.
Compression Ratio ...............................................................9.1-to-1
Air Intake System ...............................................Naturally Aspirated
Valve Seats ........................................................... Precision Ground
Lifter Type ......................Overhead Valve Push Rod/Hydraulic Lifter
Engine Parameters
Rated Synchronous RPM ..............................................60 Hz, 1800
HP at rated kW (LP/NG) ...............................................60 Hz, 64/59
Exhaust System
Exhaust Flow at Rated Output 60 Hz .................................. 274 cfm
Exhaust Temperature at Rated Output .................................. 938° F
Combustion Air Requirements (Natural Gas)
Flow at rated power, 60 Hz ................................................. 105 cfm
Governor
Type .................................................................................. Electronic
Frequency Regulation ...................................................Isochronous
Steady State Regulation ......................................................± 0.25%
Engine Lubrication System
Type of Oil Pump ...................................................................... Gear
Oil Filter ............................................... Full Flow Spin-on, Cartridge
Crankcase Oil Capacity ....................................................4 U.S. qts.
‹
‹
COOLING SYSTEM
Type ...................................................Pressurized  Closed  Recovery
Water Pump .................................................................... Belt Driven
Fan Speed .........................................................................2060 rpm
Fan Diameter .....................................................................22 inches
Fan Mode ..............................................................................Pusher
Air Flow (inlet air including alternator and
  combustion air) .......................................................... 2725 ft3/min.
Coolant Capacity ........................................................ (3.0 U.S. gal.)
Heat Rejection to Coolant ..........................................151,000 Btu/h
Maximum Operating Air Temp. on Radiator ..............60° C (150° F)
Maximum Ambient Temperature ................................50° C (140° F)
FUEL SYSTEM
Type of Fuel ......................................... Natural Gas, Propane Vapor
Carburetor ...................................................................... Down Draft
Secondary Fuel Regulator .................................................Standard
Fuel Shut-off Solenoid ........................................................Standard
Operating Fuel Pressure  ...................... 5 in. - 14 in. Water Column
Fuel Consumption - ft
3
/hr (Natural Gas/LPV)
 Exercise 
25% 
50% 
75% 
100%
 Cycle 
Load 
Load 
Load  Load
 82/33  148/59  285/114 397/160 550/221
ELECTRICAL SYSTEM
Battery Charge Alternator ............................................12V, 30 Amp
Static Battery Charger ............................................................2 Amp
Recommended Battery ................................................ 24F 525CCA
System Voltage .....................................................................12 Volts
Voltage Regulator
Type .................................................................................. Electronic
Sensing ........................................................................ Single-phase
Regulation ................................................................................± 1%
Features .................................................V/F Adjustable, Adjustable
 
Voltage and Gain LED Indicators
Power Adjustment for Ambient Conditions
Temperature Deration
  3% for every 10° C above °C ..................................................... 25
  1.65% for every 10° above °F .................................................... 77
Altitude Deration
  1% for every 100 m above m ................................................... 183
  3% for every 1000 ft. above ft. ................................................. 600
Controller ............................... R-100  (0F2752D)
‹
‹
‹
6-1
Standby Generator Sets
Specifications
GenSpec001  Rev.