Environmental Specifications 
Table 4. 
Environmental Specifications for the Cisco UCS C200 M2 Server 
 
Environment 
Specification 
Temperature operating 
10°C to 35°C (50°F to 95°F) 
Temperature nonoperating 
-40°C to 65°C (-40°F to 149°F) 
Altitude operating 
0 to 3,000 m (0 to 10,000 ft.); maximum ambient temperature decreases by 1° per 300m 
Humidity nonoperating 
5 to 93%, noncondensing 
Vibration nonoperating 
2.2 Grms, 10 minutes per axis on each of the three axes 
Shock operating 
Half-sine 2 G, 11 ms pulse, 100 pulses in each direction, on each of the three axes 
Shock nonoperating 
Trapezoidal, 25 G, two drops on each of six faces ΔV: 175 inches per second ec on bottom face drop, 
90 inches per second ec on other five faces 
Safety 
UL60 950-1 No. 21CFR1040, CAN/CSA-C22.2 No. 60950-1, IRAM IEC60950-1, CB IEC60950-1, EN 
60950-1, IEC 60950-1, GOST IEC60950-1, SABS/CB IEC6095-1, CCC
*
/CB GB4943-1995, 
CNS14336, CB IEC60950-1, AS/NZS 60950-1, GB4943 
Emissions 
47CFR Part 15 (CFR 47) Class A, AS/NZS CISPR22 Class A, CISPR2 2 Class A, EN55022 Class A, 
ICES003 Class A, VCCI Class A, EN61000-3-2, EN61000-3-3, KN22 Class A, CNS13438 Class A 
Immunity 
Verified to comply with EN55024, CISPR 24, KN 61000-4 Series, KN 24 
Electrostatic discharge 
Tested to ESD levels up to 15 kilovolts (kV) air discharge and up to 8 kV contact discharge without 
physical damage 
Acoustic 
●  Sound power: 54.7 dBA (5.7 Bels) at ambient temperature 23° C measured using the Dome 
Method 
●  GOST MsanPiN 001-96 
For More Information 
Please visi
. 
 
 
 
 
Printed in USA 
C17-644227-02  10/11