Справочник Пользователя для Cisco R200-D450GB03=
© 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 33 of 33
Environmental Specifications
Table 4.
Environmental Specifications for the Cisco UCS C200 M2 Server
Environment
Specification
Temperature operating
10°C to 35°C (50°F to 95°F)
Temperature nonoperating
-40°C to 65°C (-40°F to 149°F)
Altitude operating
0 to 3,000 m (0 to 10,000 ft.); maximum ambient temperature decreases by 1° per 300m
Humidity nonoperating
5 to 93%, noncondensing
Vibration nonoperating
2.2 Grms, 10 minutes per axis on each of the three axes
Shock operating
Half-sine 2 G, 11 ms pulse, 100 pulses in each direction, on each of the three axes
Shock nonoperating
Trapezoidal, 25 G, two drops on each of six faces ΔV: 175 inches per second ec on bottom face drop,
90 inches per second ec on other five faces
90 inches per second ec on other five faces
Safety
UL60 950-1 No. 21CFR1040, CAN/CSA-C22.2 No. 60950-1, IRAM IEC60950-1, CB IEC60950-1, EN
60950-1, IEC 60950-1, GOST IEC60950-1, SABS/CB IEC6095-1, CCC
60950-1, IEC 60950-1, GOST IEC60950-1, SABS/CB IEC6095-1, CCC
*
/CB GB4943-1995,
CNS14336, CB IEC60950-1, AS/NZS 60950-1, GB4943
Emissions
47CFR Part 15 (CFR 47) Class A, AS/NZS CISPR22 Class A, CISPR2 2 Class A, EN55022 Class A,
ICES003 Class A, VCCI Class A, EN61000-3-2, EN61000-3-3, KN22 Class A, CNS13438 Class A
ICES003 Class A, VCCI Class A, EN61000-3-2, EN61000-3-3, KN22 Class A, CNS13438 Class A
Immunity
Verified to comply with EN55024, CISPR 24, KN 61000-4 Series, KN 24
Electrostatic discharge
Tested to ESD levels up to 15 kilovolts (kV) air discharge and up to 8 kV contact discharge without
physical damage
physical damage
Acoustic
● Sound power: 54.7 dBA (5.7 Bels) at ambient temperature 23° C measured using the Dome
Method
● GOST MsanPiN 001-96
For More Information
Please visit
Printed in USA