Справочник Пользователя для Yamaha 007POTO-G0

Скачать
Страница из 290
MIDI Data Format
267
LS9-16/32  Owner’s Manual
Appendices
4.8 FUNCTION CALL – CHANNEL –
4.8.1
Pair ON/OFF Trigger Format (PARAMETER CHANGE)
Receive
Data will be received when [PARAMETER CHANGE Rx] is on and the Device 
number of both [Rx CH] and SUB STATUS are matched. The data will be 
echoed when [PARAMETER CHANGE ECHO] is on.
4.8.2
Module Name
4.9  LEVEL METER DATA
4.9.1
Format (PARAMETER CHANGE)
When transmission is enabled by receiving Request for Level Meter, the 
corresponding metering data will be sent in every 50 millisecond for 10 seconds. 
If metering information is expected to be continuously sent, Request is needed 
to be sent in at least every 10 seconds.
Receive
The data will be echoed when [PARAMETER CHANGE ECHO] is ON.
Transmission
When transmission is enabled by receiving Request, the corresponding metering 
data will be sent in constant interval for a given period of time (The interval and 
time will vary depending on devices). When rebooted or port setting is changed, 
the transmission will be disabled.
When [PARAMETER CHANGE ECHO] is on, the message will be sent as it is.
4.9.2
Format (PARAMETER REQUEST)
Receive
Data will be received when [PARAMETER CHANGE Rx] is on and the Device 
number of both [Rx CH] and SUB STATUS are matched. The data will be 
echoed when [PARAMETER CHANGE ECHO] is on. the corresponding 
metering data will be sent via [Rx CH] in constant interval for a given period of 
time (The interval and time will vary depending on devices).
When Address UL = 0x7F is received, all metering data transmission will be 
immediately stopped [disabled].
Transmission
When [PARAMETER CHANGE ECHO] is on, the message will be sent as it is.
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacture’s ID number (YAMAHA)
SUB STATUS
0001nnnn 1n
n=0-15 (Device number=MIDI Channel)
GROUP ID
00111110 3E
Digital mixer
MODEL ID
00010010 12
LS9
DATA 
CATEGORY
00000000 00
OTHER DATA
FUNCTION 
NAME
01000011 "C"
01101000 "h"
01101100 "l"
01010000 "P"
01101001 "i"
01110010 "r"
01000011 "C"
01110000 "p"
MODULE NAME 0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
DATA
0sssssss sh
Source Channel Number H  *1)
0sssssss sl
Source Channel Number L  *1)
0ddddddd dh
Destination Channel Number H  *1)
0ddddddd dl
Destination Channel Number L  *1)
EOX
11110111 F7
End of exclusive
MODULE NAME
Pair On (with Copy)
”PAIRONCP”
Pair On (with Reset Both)
”PAIRONRS”
Pair Off
”PAIROFF_”
*1) 0:CH1–63:CH64
256:MIX 1– 271:MIX 16
512:MATRIX 1–519:MATRIX 8
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacture’s ID number (YAMAHA)
SUB STATUS
0001nnnn 1n
n=0-15 (Device number=MIDI Channel)
GROUP ID
00111110 3E
Digital mixer
MODEL ID
00010010 12
LS9
DATA 
CATEGORY
00100001 21
REMOTE LEVEL METER
DATA
0mmmmmmm mm
ADDRESS UL
0mmmmmmm mm
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
0ddddddd dd
Data1
:
:
EOX
11110111 F7
End of exclusive
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacture’s ID number (YAMAHA)
SUB STATUS
0011nnnn 3n
n=0-15 (Device number=MIDI Channel)
GROUP ID
00111110 3E
Digital mixer
MODEL ID
00010010 12
LS9
DATA 
CATEGORY
00100001 21
REMOTE LEVEL METER
DATA
0mmmmmmm mm
ADDRESS UL
0mmmmmmm mm
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
0ccccccc ch
Count H
0ccccccc cl
Count L
EOX
11110111 F7
End of exclusive