EUROPOWER PMP1000/PMP3000/PMP5000
5  WIRING EXAMPLES
5 WIRING EXAMPLES
Fig. 5.1: Stereo operation
For stereo operation the POWER AMP switch 
 must be set
to its upper position (MAIN or MAIN L/MAIN R). Outputs A and B
provide the stereo main signal for passive speakers. The preamp
monitor output is connected to two parallel active speakers,
which are used as on-stage monitors. Use the footswitch to
enable/disable the effects processor.
Fig. 5.2: Bridged mono operation
This illustration shows the power mixer with a sub-woofer
connected to OUTPUT B. For a bridged mono operation to
OUTPUT B, the AMP MODE selector switch 
  must be set to
its  lower position “BRIDGE”. A separate stereo power amp
(BEHRINGER EUROPOWER EP1500) connected to the preamp
main outputs delivers the stereo main signal. Two active monitor
speakers for on-stage operation are connected to the preamp
monitor output.