7
 - 5
7.2 For Use in Normal System Configuration
7.2.1 Before creating a program
7
PROGRAMMING
(2) Intelligent function module switch setting
Based on the setting conditions given in Section 7.2 (2), make the intelligent function 
module switch settings.
(a) Each switch setting
1) Switch 1: CH1 setting
2) Switch 2: CH2 setting
3) Switch 3, switch 4, switch 5: Use prohibited (0: fixed)
 *   If any other than 0 is set to the switches from 1 to 5 where 0 is fixed, the functions of the QD64D2 
are not guaranteed. 
(b) Write the settings in (a) to the QD64D2.
On GX Developer's "Parameter setting" screen, select the "I/O assignment" tab, 
click "Switch setting", and make settings of Switch 1 to 5 on the screen shown 
below.
H
0
0
0
2
CH1: 2
(CW/CCW)
0
0
0
0
0
0
0
0
b9
b10
b11
b12
b13
b14
b8
b15
<Switch 1>
Pulse input mode
Use prohibited (0: fixed*)
Counter format
CH1: 0 (Linear counter)
Counter value comparison function 
selection
CH1: 0 (Coincidence output function)
0: fixed*
0: fixed*
H
1
1
0
2
CH2: 2
(CW/CCW)
0
0
0
1
0
0
0
1
b9
b10
b11
b12
b13
b14
b8
b15
<Switch 2>
Pulse input mode
Use prohibited (0: fixed*)
Counter format
CH2: 1 (Ring counter)
Counter value comparison 
function selection
CH2: 1 (Continuous comparison 
function)
0: fixed*
0: fixed*
H
Fixed at 0
0 0 0 0
<Switch 3 to 5>