5 - 8 
MELSEC-Q
 
5   DATA USED FOR POSITIONING CONTROL 
5.1.3 Setting items for OPR parameters 
When carrying out "OPR control", the "OPR parameters" must be set. The setting 
items for the "OPR parameters" are shown below. 
The "OPR parameters" are set commonly for each axis. 
Refer to Chapter 8 "OPR control" for details on the "OPR control", and to Section 5.2 
"List of parameters" for details on each setting item. 
 
OPR control 
 
OPR parameters 
Machine OPR control 
Fast  
OPR control 
Pr.43   OPR method 
Near-poi
nt
 dog 
m
et
hod 
Count
 m
et
hod 1) 
Count
 m
et
hod 2) 
Dat
a s
et
 m
et
hod 
Pr.44   OPR direction 
 
 
 
 
Pr.45   OP address 
 
 
 
 
Pr.46   OPR speed 
 
 
 
– 
Pr.47   Creep speed 
 
 
 
– 
OP
R bas
ic
 param
et
ers
 
Pr.48   OPR retry 
– 
Pr.50  
Setting for the movement amount after near-
point dog ON 
– 
 
 
– 
Pr.51   OPR acceleration time selection 
 
 
 
– 
Pr.52   OPR deceleration time selection 
 
 
 
– 
Pr.53   OP shift amount 
S S S – 
Pr.54   OPR torque limit value 
 
 
 
– 
Preset parameters 
are used for 
machine OPR 
control. 
Pr.55   Operation setting for incompletion of OPR 
 
 
 
 
– 
Pr.56   Speed designation during OP shift 
– 
OP
R det
ai
led param
et
ers
 
Pr.57   Dwell time during OPR retry 
– 
Preset parameters 
are used for 
machine OPR 
control. 
 
   : Always set 
    :  Set as required 
 –  :  Setting not required (This is an irrelevant item, so the setting value will be ignored. If the value is the default 
value or within the setting range, there is no problem.) 
 R  :  Set when using the "12.2.1 OPR retry function". ("–" when not set.) 
 S  :  Set when using the "12.2.2 OP shift function". ("–" when not set.) 
 
 Checking the OPR parameters. 
 
Pr.43
to 
Pr.57
 are checked with the following timing. 
 
(1)  When the "PLC READY signal [Y0]" output from the PLC CPU to the QD75MH 
changes from OFF to ON 
(2)  When the test operation button is turned ON in the test mode using GX 
Configurator-QP 
(3)  When an error check is carried out with GX Configurator-QP