Справочник Пользователя для Mitsubishi Electronics QD75MH4

Скачать
Страница из 838
 
 
 
8 - 16 
MELSEC-Q
 
8   OPR CONTROL 
 
8.4 Selection of the OPR setting condition 
8.4.1 Outline of the OPR setting condition 
If executing the home position return (OPR), it is necessary to make sure that the 
servomotor has been rotated more than one revolution and passed the Z phase (Motor 
reference position signal) and that the zeroing pass signal ( 
Md.108
 Servo status : b4) 
has turned ON. 
However, if selecting "1: It is not necessary to pass through the Z phase after the 
power on." with " 
Pr.180
 Function selection C-4", it is possible to turn the zeroing pass 
point signal (
Md.108
 Servo status : b4) ON without passing the zero point. 
 Data setting 
 
To select the "OPR setting condition", set the data shown in the following table to 
the QD75MH using the peripheral device. 
Servo parameters are set for each axis. 
 
The "OPR setting condition" is stored into the following buffer memory addresses.  
 
Buffer memory address 
Setting item 
Setting 
value 
Setting details 
Axis 1  Axis 2  Axis 3  Axis 4 
Pr.180
 
Function selection 
C-4 (PC17) 
0 : Need to pass motor Z phase after the 
power supply is switched on. 
1 : Not need to pass motor Z phase after 
the power supply is switched on.  
30180 30380 30580 30780 
 
 Refer to Section 5.2.9 "Servo parameters (Expansion setting)" for information on the storage details. 
 
 Precautions during operation 
 
(1)  If setting the above servo parameter to "1: It is not necessary to pass through 
the Z phase after the power on.", the restriction, "If executing the home 
position return (OPR), it is necessary to execute OPR after rotating the 
servomotor more than one revolution and letting it pass through the Z phase 
(Motor reference position signal).", will be invalid. 
 
(2)  Set the parameter value and switch power off once (The parameter is 
transferred to servo amplifier from QD75MH), then switch it on again to make 
that parameter setting valid.