Справочник Пользователя для Mitsubishi Electronics QD75MH4

Скачать
Страница из 838
 
 
 
9 - 4 
MELSEC-Q
 
9   MAJOR POSITIONING CONTROL 
 
9.1.1 Data required for major positioning control 
The following table shows an outline of the "positioning data" configuration and setting 
details required to carry out the "major positioning controls". 
 
Setting item 
Setting details 
 Da.1   Operation pattern 
Set the method by which the continuous positioning data (Ex: positioning data No. 1, 
No. 2, No. 3) will be controlled. (Refer to Section "9.1.2".) 
 Da.2   Control system 
Set the control system defined as a "major positioning control". (Refer to Section "9.1".) 
 Da.3  
Acceleration time 
No. 
Select and set the acceleration time at control start. (Select one of the four values set 
in
Pr.9
Pr.25
Pr.26
, and 
Pr.27
 for the acceleration time.) 
 Da.4  
Deceleration time 
No. 
Select and set the deceleration time at control stop. (Select one of the four values set 
in
Pr.10
Pr.28
Pr.29
, and 
Pr.30
 for the deceleration time.) 
 Da.5  
Axis to be 
interpolated 
Set an axis to be interpolated (partner axis) during the 2-axis interpolation operation 
(Refer to Section 9.1.6). 
 Da.6  
Positioning address/ 
movement amount 
Set the target value during position control. (Refer to Section "9.1.3".) 
 Da.7   Arc address 
Set the sub point or center point address during circular interpolation control. 
 Da.8   Command speed 
Set the speed during the control execution. 
 Da.9   Dwell time 
Set the time the machine waits from the completion of the executed positioning control 
and the stopping of the workpiece until the judgment of the QD75MH positioning 
completion. 
Positioning data N
o. 1 
 Da.10   
M code 
Set this item when carrying out sub work (clamp and drill stops, tool replacement, etc.) 
corresponding to the code No. related to the positioning data execution. 
 
 The settings and setting requirement for the setting details of 
Da.1
 to 
Da.10
 differ according to the 
"
 Da.2 
Control system". (Refer to Section 9.2 "Setting the positioning data".) 
 
 Major positioning control sub functions 
 
Refer to Section 3.2.4 "Combination of QD75MH major functions and sub 
functions" for details on "sub functions" that can be combined with the major 
positioning control.   
Also refer to Chapter 12 "Control sub Functions" for details on each sub function. 
 
 Major positioning control from peripheral devices 
 
"Major positioning control" can be executed from the peripheral device test mode.  
Refer to GX Configurator-QP Operating Manual for details on carrying out major 
positioning control from the peripheral device.  
 
REMARK 
 600 positioning data (positioning data No. 1 to 600) items can be set per axis.