10 - 2 
MELSEC-Q
 
10   HIGH-LEVEL POSITIONING CONTROL 
 
10.1 Outline of high-level positioning control 
In "high-level positioning control" the execution order and execution conditions of the 
"positioning data" are set to carry out more applied positioning. (The execution order 
and execution conditions are set in the "block start data" and "condition data".) 
The following applied positioning controls can be carried out with "high-level positioning 
control".  
 
High-level positioning 
control 
Details 
Block  1 start 
(Normal start) 
With one start, executes the positioning data in a random block with the set order. 
Condition start 
Carries out condition judgment set in the "condition data" for the designated 
positioning data, and then executes the "block start data".  
• When the condition is established, the " block start data" is executed.  
• When not established, that " block start data" is ignored, and the next point's " block 
start data" is executed. 
Wait start 
Carries out condition judgment set in the "condition data" for the designated 
positioning data, and then executes the " block start data".  
• When the condition is established, the " block start data" is executed.  
• When not established, stops the control until the condition is established. (Waits.) 
Simultaneous start 
Simultaneously executes the positioning data having the No. for the axis designated 
with the "condition data". (Outputs pulses at the same timing.) 
Repeated start (FOR 
loop) 
Repeats the program from the " block start data" set with the "FOR loop" to the " 
block start data" set in "NEXT" for the designated No. of times. 
Repeated start (FOR 
condition) 
Repeats the program from the " block start data" set with the "FOR condition" to the " 
block start data" set in "NEXT" until the conditions set in the "condition data" are 
established. 
 
 High-level positioning control sub functions 
 
"High-level positioning control" uses the "positioning data" set with the "major 
positioning control". Refer to Section 3.2.4 "Combination of QD75MH main 
functions and sub functions" for details on sub functions that can be combined with 
the major positioning control. 
Note that the sub function Section 12.7.8 "Pre-reading start function" cannot be 
used together with "high-level positioning control". 
 
 High-level positioning control from peripheral devices 
 
"High-level positioning control" (start of the "block start data") can be executed 
from GX Configurator-QP test mode.  
Refer to GX Configurator-QP Operating Manual for details on starting of the "block 
start data" from GX Configurator-QP.  
 
REMARK 
Block  1:  
"1 block" is defined as all the data continuing from the positioning data in which 
"continuous positioning control" or "continuous path control" is set in the 
operation pattern (
Da.1
) to the positioning data in which "independent 
positioning control (Positioning complete)" is set.  
 
Simultaneous start  2:  
Besides the simultaneous start of "block start data" system, the "simultaneous 
starts" include the "multiple axes simultaneous start control" of control system. 
Refer to Section 10.5 "Multiple axis simultaneous start control" for details.