Справочник Пользователя для Mitsubishi Electronics QD75MH4

Скачать
Страница из 838
 
 
 
12 - 59 
MELSEC-Q
 
12   CONTROL SUB FUNCTIONS 
 
12.6 Absolute position system 
The QD75MH can construct an absolute position system by installing the absolute 
position system and connecting it through SSCNET   . 
The following describes precautions when constructing the absolute position system. 
 
Servomotor
Servo amplifier
Position command
Control command
Servo parameter
QD75MH
Monitor data
PLC
CPU
OPR
address
M
PLG
Absolute position detector
Back-up
Return of the present value
Battery
Position command
Control command
Servo parameter
Monitor data
 
 
Fig. 12.33 Configuration of absolute position system 
 
[1]   Setting for absolute positions 
When constructing an absolute position system, use a servomotor with absolute 
position detector. 
It is also necessary to install a battery for retaining the location of the OPR in the 
servo amplifier. When an absolute position detector is installed, the " 
Pr.103
 
Absolute position detection system" is selected "1: Valid" in the amplifier setting 
for the servo parameters (basic setting). 
 
Axis No. 
Axis 1 
Axis 2 
Axis 3 
Axis 4 
Buffer memory 
30103 
30303 
30503 
30703