Appendix 3 Connection with servo amplifiers 
Appendix 3.1 Connection of SSCNET   cables 
 
(1)   Connection 
The connection method of SSCNET   cable between QD75MH and servo 
amplifier is explained as follows. 
When absolute position detection control is executed, installed battery (Q6BAT) 
to servo amplifier. 
 
QD75MH
Servo amplifier
CN1A
CN1B
CN1A
CN1B
 : When it makes a mistake in the connection of CN1A and CN1B, 
     it is not possible to communicate. 
SSCNET    Cable length
  When MR-J3BUS    M is used
  1)     3m
  When MR-J3BUS    M-A is used
  1)     20m
  When MR-J3BUS    M-B is used
  1)     50m
cap
SSCNET    connector
Servo amplifier
1)
1)
 
 
 
No. Model 
name 
 Cable 
length 
Description 
MR-J3BUS†
0.15m(0.49ft.), 0.3m(0.98ft.), 
0.5m(1.64ft.), 1m(3.28ft.), 
3m(9.84ft.) 
Standard code for inside panel. 
MR-J3HBUS†M-A 
5m(16.40ft.), 10m(32.81ft.), 
20m(65.62ft.) 
Standard code for outside panel. 
1) 
MR-J2HBUS†M-B 
30m(98.43ft.), 40m(131.23ft.), 
50m(164.04ft.) 
Long distance cable. 
• Connection between 
QD75MH† and MR-J3-B. 
• Connection between MR-J3-B 
and MR-J3-B. 
† = Cable length 
 
 
!
 CAUTION 
 Please connect the SSCNET   cable with the above-mentioned connector. When the connection is 
mistaken, the communication between QD75MH and the servo amplifier cannot be done. 
 SSCNET   connector is put a cap to protect light device inside connector from dust. 
For this reason, do not remove a cap until just before mounting SSCNET   cable. 
Then, when removing SSCNET   cable, make sure to put a cap.