Справочник Пользователя для Mitsubishi Electronics QCPU

Скачать
Страница из 1204
6-104
EDCON(P)
6.3.17  
Double precision
 
to
 
Single precision conversion 
(EDCON(P))
EDCON(P)
Function
Converts 64-bit floating-point real number specified for 
 into 32-bit floating-point real 
number, and stores the conversion result to the device specified for 
.
Operation Error
(1) In any of the following cases, an operation error occurs, the error flag (SM0) turns ON, and 
an error code is stored into SD0.
 • The value of the specified device is not in the following range:
(Error code: 4140)
0,2
-1022
 
 | value of specified device |   2
1024
 • The value of the designated device is  0. 
(Error code: 4140)
 • The result exceeds the following range (Conversion results in an overflow):
2
128
 
 | Conversion result | 
  (Error code: 4141)
: Conversion source data, or head number of the device where conversion source data is stored
(Real number (double precision))
: Head number of the device where the converted data is stored (Real number (single precision))
Setting 
Data
Internal Devices 
R, ZR
J
\
U
\G
Zn
Constants
E
Other
Bit
Word
Bit
Word
––
––
––
––
––
––
––
––
Universal
Basic
Process
High
performance
Redundant
EDCON
EDCONP
S
D
S
D
EDCON
EDCONP
Command
Command
S
D
S
D
S
D
+1
D
D
32-bit floating-point real number
+3
+2
+1
S
64-bit floating-point real number
S
S
S