Справочник Пользователя для Studer Innotec C1312 COMPACT

Скачать
Страница из 23
STUDER INNOTEC 
   
                                                        
COMPACT
COMPACT
COMPACT
COMPACT
 
 
User manual 
COMPACT V2.0 E 
20 
 
5.3.2 Set the voltage and timing 
threshold 
The programming is done in accordance 
with the following steps: 
 
Push and hold down, the Push Button 21 
(Program) and the Push Button 19 
(Change status) for minimum  2 seconds 
simultaneously. 
With the Push Button 20 (select) select 
with of the battery level and the absorption 
time to be changed. 
 
These four red LED show the function 
set: 
Low voltage 
LED 13 
Float charge 
LED 12 
Absorption (End of charge) 
LED11 
Equalization LED 
10 
Absorptions Time 
LED 10/11/12/13 
 
With the Push Button 19 (Change status) set the desired parameter (voltage or the time) to modify 
(LED 14/15/16/17/18). Push Button 19 (Change status) to set the desired value according to the 
the table  5.3.1.  
If desired, repeat the operation with any other parameter (voltage or time) to be changed.  
If during 10 seconds no buttons are pressed, the selected values are automatically stored and the 
COMPACT switches back in to the normal operating status. 
 
The voltage levels and times changed through programming are only first active with the 
next charge cycle! 
The voltage level which are not suitable can greatly reduce the battery life or could even 
destroy it ! Therefore check beforehand with your battery supplier. 
 
5.4  Program the auxiliary contact 
5.4.1 Principle 
The Auxiliary Contact can be basically programmed for any operating situation of the COMPACT 
which is indicated with a LED. The programming is possible for one or more operating situations. If 
the contact is programmed for many situations, it is activated as soon as the COMPACT finds itself 
in any one of the programmed situations. That means that workings of the contact meets that of 
the logic OR–Function. 
5.4.2  The programming of the Auxiliary Contact is carried out in the following Steps: 
The Push Button 21 (Program) press down for min. 2 seconds. The LED 4 „Program“ is lit as an 
indication, that the COMPACT is in program mode. 
A lit LED shows the programmed condition for the auxiliary contact. (LED 10/11/12/13 factory 
setting) 
With the Push Button 20 (select), select the desired condition in which the contact should be 
activated. 
With the Push Button 19 (Change status) confirm or change the status for this condition. 
If desired ,with the Push Button 20 (select) select another condition in which the contact should be 
activated. 
With the Push Button 19 (Change status) confirm or change the status for this condition. 
If during 10 seconds no buttons are pushed, then the settled values are automatically stored and 
the COMPACT switches back to normal operating condition. 
OFF
Over Temp
Overload
ON/OFF
Batt Low/High
(Change status)
lock
RESET ALARM
3
4
5
6
20
10
11
12
14
21
13
19
15
16
17
18