Справочник Пользователя для Elektra Beckum Mega 350 D
15
ENGLISH
• Motor protection tripped, e.g. by
insufficient cooling (cooling fins cov-
ered).
− Switch compressor OFF at the
ered).
− Switch compressor OFF at the
On/Off switch; remove cause for
overheating; let cool off for
approx. 10 minutes; reset the
motor protection switch; switch
compressor ON again at the On/
Off switch.
overheating; let cool off for
approx. 10 minutes; reset the
motor protection switch; switch
compressor ON again at the On/
Off switch.
Compressor runs but does not build
up sufficient pressure.
up sufficient pressure.
• Condensate drain of pressure ves-
sel leaky.
− Check gasket of drain cock(s);
− Check gasket of drain cock(s);
replace if necessary.
− Tighten drain cock(s) fingertight.
• Check valve leaky.
− Have check valve serviced by
qualified service centre.
Air tool is not supplied with sufficient
pressure.
pressure.
• Pressure regulator not opened wide
enough.
− Open pressure regulator more.
− Open pressure regulator more.
• Hose connection between compres-
sor and air tool leaky.
− Check air hoses, replace defec-
− Check air hoses, replace defec-
tive parts if necessary.
A
Danger!
Repairs to power tools must be
Repairs to power tools must be
carried out by qualified electricians
only!
only!
Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address.
send to the service centre in your coun-
try. See spare parts list for address.
Please attach a description of the fault to
the power tool.
the power tool.
The machine's packaging can be 100 %
recycled.
recycled.
Worn out devices and accessories con-
tain considerable amounts of valuable
raw and plastic materials, which can be
recycled.
tain considerable amounts of valuable
raw and plastic materials, which can be
recycled.
These instructions are printed on chlo-
rine-free bleached paper.
rine-free bleached paper.
8.
Repairs
9.
Environmental protection
10. Technical specifications
Suction capacity l/min
290
Free air delivery (volume flow rate)
l/min
165
Filling rate
l/min
195
Working pressure (compression end pressure)
bar
10
Pressure vessel volume
l
50
No. of air outlets
2
Compressor pump model
B 2800
No. of cylinders
2
Speed (compressor pump)
min
-1
1300
Motor capacity
kW
2.0
Supply voltage (50 Hz)
V
400
Rated current
A
3.7
Fuse protection min.
A
10 (time-lag)
Degree of protection
IP 44
Maximum overall length when using extension cables with:
– 3 x 1.5 mm
– 3 x 1.5 mm
2
lead cross-section
– 3 x 2.5 mm
2
lead cross-section
m
m
m
100
160
160
Oil grade
10 W 40
Oil qantity for oil change
l
0.21
Dimensions: length x width x height
cm
88 x 49 x 77
Weight kg
46
Sound pressure level L
PA
at 4 m maximum
dB (A)
71 ± 3
Sound power level L
WA
dB (A)
91 ± 3