Справочник Пользователя для Elektra Beckum Mega 500 W
15
ENGLISH
A
Danger!
Prior to all servicing:
Prior to all servicing:
− Switch Off.
− Unplug.
− Wait until the compressor has
− Unplug.
− Wait until the compressor has
come to a complete stop.
− Ensure the compressor and all air
tools and accessories connected
to it are relieved from pressure.
to it are relieved from pressure.
After all servicing:
− Check to see that all safety
devices are operational.
− Make sure that no tools or other
parts remain on or in the
machine.
machine.
Compressor does not run:
• No mains voltage.
− Check cables, plug, outlet and
mains fuse.
• Mains voltage too low.
− Use only extension cables with
sufficient lead cross section (see
"Technical Specifications"). Avoid
using extension cable with cold
machine.
"Technical Specifications"). Avoid
using extension cable with cold
machine.
• Compressor was stopped by
unplugging.
− Switch compressor OFF at the
− Switch compressor OFF at the
On/Off switch, then ON again.
• Motor has overheated, caused by
insufficient cooling (cooling fins cov-
ered).
− Remove cause for overheating
ered).
− Remove cause for overheating
and allow to cool down for
approx. 10 minutes, then start
again.
approx. 10 minutes, then start
again.
Compressor runs but does not build
up sufficient pressure.
up sufficient pressure.
• Drain cock on cup of filter/regulator
unit open.
− Close drain cock.
− Close drain cock.
• Check valve leaky.
− Have check valve serviced by
qualified service centre.
Air tool is not supplied with sufficient
pressure.
pressure.
• Pressure regulator not opened wide
enough.
− Open pressure regulator more.
− Open pressure regulator more.
• Hose connection between compres-
sor and air tool leaky.
− Check air hoses, replace defec-
− Check air hoses, replace defec-
tive parts if necessary.
A
Danger!
Repairs to electric tools must
Repairs to electric tools must
be carried out by qualified electrici-
ans only!
ans only!
Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address.
send to the service centre in your coun-
try. See spare parts list for address.
Please attach a description of the fault to
the electric tool.
the electric tool.
The machine's packaging can be 100 %
recycled.
recycled.
Worn out machines and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.
rine-free bleached paper.
7.
Trouble Shooting
8.
Repairs
9.
Environmetal protection
10. Technical Specifications
Suction capacity
l/min
380
Free air delivery (volume flow rate)
l/min
240
Filling rate
l/min
280
Working pressure (compression end pressure)
bar
10
Pressure vessel volume
l
60
No. of air outlets
2
Compressor pump type
B 3800 B
No. of cylinders
2
Speed (compressor pump)
min
-1
1150
Motor capacity
kW
2.2
Supply voltage (50 Hz)
V
230
Rated current
A
12.5
Fuse protection min.
A
16 (time-lag)
Degree of protection
IP 54
Max. overall cable length when using extension cables:
– at 3 x 1.5 mm
– at 3 x 1.5 mm
2
lead cross section
– at 3 x 2.5 mm
2
lead cross section
m
m
m
15
25
25
Oil grade (compressor pump)
SAE 40
Required oil quantity (compressor pump)
l
1.0
Dimensions length x width x height
cm
110 x 46 x 81
Weight
kg
79
Sound pressure level L
PA
at 4 m max.
dB (A)
72 ± 3
Sound power level L
WA
dB (A)
92