6 - 9
MDS-D-SVJ3/SPJ3 Series Specifications Manual
6-6 Surge absorber
6-6 Surge absorber
When controlling a magnetic brake of a servomotor in DC OFF circuit, a surge absorber must be installed to 
protect the relay contacts and brakes. Commonly a varistor is used.
(1) Selection of varistor
When a varistor is installed in parallel with the coil, the surge voltage can be adsorbed as heat to protect a 
circuit. Commonly a 120V product is applied. When the brake operation time is delayed, use a 220V product. 
Always confirm the operation with an actual machine.
(2) Specifications
Select a varistor with the following or equivalent specifications. To prevent short-circuiting, attach a flame 
resistant insulation tube, etc., onto the leads as shown in the following outline dimension drawing.
Varistor specifications
(Note 1) Selection condition: When ON/OFF frequency is 10 times/min or less, and exciting current is 2A or 
less
(Note 2) ERZV10D121 and ERZV10D221 are manufactured by Matsushita Electric Industrial Co., Ltd.
TNR10V121K and TNR10V221K are manufactured by MARCON Electronics Co., Ltd. 
Contact: Matsushita Electronic Components Co., Ltd: http://www.panasonic.co.jp/ maco/
MARCON Electronics Co., Ltd.   Telephone:   
(Kanto)03-3471-7041 (+81-3-3471-7041)
(Kinki) 06-6364-2381 (+81-3-6364-2381)
(Chubu) 052-581-2595 (+81-52-581-2595)
(3) Outline dimension drawing
ERZV10D121, ERZV10D221
Varistor type
Varistor 
voltage 
rating 
(range)
Rating
Max. limit 
voltage
Electro-
static 
capacity 
(reference 
value)
Tolerable circuit 
voltage
Surge current 
withstand level 
(A)
Energy
 withstand level 
(J)
Power
(V)
AC(V)
DC(V)
1 time
2 times
10/
1000
μs
2ms
(W)
(V)
(pF)
ERZV10D121
120
(108 to 132)
75
100
3500
2500
20
14.5
0.4
200
1400
TND10V-121K
ERZV10D221
220
(198 to 242)
140
180
3500
2500
39
27.5
0.4
360
410
TND10V-221K
Normally use a product with 120V varistor voltage. If there is no allowance for the brake operation 
time, use the 220V product. A varistor whose voltage exceeds 220V cannot be used, as such varistor 
will exceed the specifications of the relay in the unit.
[Unit:mm]
Insulation tube
11.5
20.0
 
POINT