Appendix 1 - 3
MDS-D-SVJ3/SPJ3 Series Specifications Manual
Appendix 1-1 Selection of cable
(2) Cable assembly
Assemble the cable with the cable shield wire securely connected to the ground plate of the connector. 
(3) Battery connection cable
Two core shield cable structure drawing
Core identification
Wire type 
(other manufactur-
er's product)
Finish 
outer 
diame-
ter
Sheath 
material
No. of 
pairs
Wire characteristics
Configura-
tion
Conduc-
tive
resistor
With-
stand 
voltage
Insulation 
resistance
Heat 
resistance 
tempera-
ture
Minimum 
bend radius
J14B101224-00
Two core shield ca-
ble
3.3mm
PVC
1
(0.2mm
2
)
7strands /
0.2mm
91.2
Ω/km
or less
AC500V/
1min
1000M
Ω/
km
or less
80°C
R33mm
No.
Insulator color
1
Red
2
Black
Core wire
Shield
(external conductor)
Sheath
Connect with a ground 
plate of connector.
 
 
 
1
2
 
JUNFLON ETFE wire 
Sheath
Shield
R