Справочник Пользователя для Mitsubishi Electronics MDS-R

Скачать
Страница из 362
 
5. Peripheral Devices 
 
 
 
 
 
5 - 9
5-6  Surge absorber 
When controlling a magnetic brake of a servomotor in DC OFF circuit, a surge absorber must be 
installed to protect the relay contacts and brakes. Commonly a varistor is used. 
 
(1)  Selection of varistor 
When a varistor is installed in parallel with the coil, the surge voltage can be adsorbed as heat to 
protect a circuit. Commonly a 120V product is applied. When the brake operation time is delayed, 
use a 220V product. Always confirm the operation with an actual machine. 
 
 
(2) Specifications 
Select a varistor with the following or equivalent specifications. To prevent short-circuiting, attach a 
flame resistant insulation tube, etc., onto the leads as shown in the following outline dimension 
drawing. 
 
Varistor specifications 
Rating 
Varistor 
voltage 
rating 
(range) 
Tolerable circuit 
voltage 
Surge current 
withstand level
(A) 
Energy 
withstand level
(J) 
Power 
Max. limit 
voltage 
Electrostatic
capacity 
(reference 
value) 
Varistor type 
(V) 
AC (V) 
DC (V)
1 time
2 times
10/1000μs
2ms (W)  (V) 
(pF) 
ERZV10D121 
TNR10V121K 
120 
(108 to 132)
75 100 
3500
2500
20 14.5 
0.4 200  1400 
ERZV10D221 
TNR10V221K 
220 
(198 to 242)
140 180 3500
2500
39 27.5 0.4  360  410 
(Note 1) Selection condition: When ON/OFF frequency is 10 times/min or less, and exciting current is 2A or less 
(Note 2) ERZV10D121 and ERZV10D221 are manufactured by Matsushita Electric Industrial Co., Ltd.  
TNR10V121K and TNR10V221K are manufactured by MARCON Electronics Co., Ltd. 
Contact: Matsushita Electronic Components Co., Ltd   : http://www.panasonic.co.jp/ maco/ 
MARCON Electronics Co., Ltd.   :Telephone (Kanto)03-3471-7041 (+81-3-3471-7041) 
(Kinki) 06-6364-2381 (+81-3-6364-2381) 
(Chubu) 052-581-2595 (+81-52-581-2595) 
 
(3)  Outline dimension drawing 
 ERZV10D121, ERZV10D221 
Unit: [mm]
 
 
 
 
 
 
 
 
 
POINT
 
Normally use a product with 120V varistor voltage. If there is no allowance for the 
brake operation time, use the 220V product. A varistor whose voltage exceeds 220V 
cannot be used, as such varistor will exceed the specifications of the relay in the unit.
 
11.5 
Insulation tube
20.0