Справочник Пользователя для Mitsubishi Electronics MDS-R

Скачать
Страница из 362
 
Appendix 1. Cable and Connector Specifications 
 
 
 
 
 
A1 - 23
 
(5)  Soldering a contact 
Temporarily solder each contact and core wire, and then solder the core wire on the contact. 
When using a drain wire, attach a heat shrink tube on it after soldering. 
(Note) Take care not to stick out the core wire from the contact. 
Take care to prevent solder from adhering to the edge of solder cup. 
 
Connector name 
Applicable contact
Applicable cable 
CM10-AP10S CM10-#22SC-S1 AWG20 or less 
CM10-AP2S 
CM10-#22SC-S2 
AWG16 or less 
 
 
 
Solder 
A
Contact 
Core wire
Cable 
Detail A 
Drain wire
Heat shrink tube
Soldering drain wire