TROUBLESHOOTING  AND  REPAIR
Observe Safety Guidelines
detailed in the beginning of this manual.
Troubleshooting Guide –
See Wiring Diagrams for location of specified
components and for troubleshooting of specific circuits.
F-10
F-10
POWER  MIG®  215
If  for  any  reason  you  do  not  understand  the  test  procedures  or  are  unable  to  perform  the  tests/repairs  safely,  contact  the
Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.  Call 1-888-935-3877
CAUTION
WELDING PROBLEMS
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
The  weld  bead  is  narrow  or  ropy.
May  have  porosity  with  the  elec-
trode stubbing into the plate.
The contact tip seizes in the gas dif-
fuser.
1. Make  sure  the    welding  proce-
dures  and  electrode  polarity  are
correct  for  the  process  being
used.
2. Make certain the shielding gas is
correct and the flow is proper.
3. Make  sure  the  weld  joint  is  not
“contaminated”.
1. The tip is being over heated due
to  excessive  current  and/or  high
duty cycle.
2. A light application of high temper-
ature anti-seize lubricant may be
applied to the contact tip threads.
2. The output capacitors may be faulty.
Check  for  loose  connections  at  the
capacitors.    Also  check  for  leaky
capacitors.  Replace if necessary.
WARNING:  The  liquid  electrolyte  in
these capacitors is toxic.  Avoid con-
tact with any portion of your body.