CUTTING SPARKS can
cause fire or explosion.
4.a.  Remove  fire  hazards  from  the  plasma  cut-
ting or gouging area. If this is not possible, cover
them  to  prevent  the  cutting  or  gouging  sparks
from  starting  a  fire.  Remember  that  welding
sparks and hot materials from plasma cutting or gouging can
easily  go  through  small  cracks  and  openings  to  adjacent
areas. Avoid cutting or gouging near hydraulic lines. Have a
fire extinguisher readily available.
4.b. Where compressed gases are to be used at the job site, spe-
cial  precautions  should  be  used  to  prevent  hazardous  situa-
tions.  Refer  to  “Safety  in  Welding  and  Cutting”  (ANSI
Standard Z49.1) and the operating information for the equip-
ment being used.
ARC RAYS can burn.
2.a. Use safety glasses and a shield with the prop-
er filter and cover plates to protect your eyes from
sparks and the rays of the arc when performing or
observing  plasma  arc  cutting  or  gouging.
Glasses,headshield and filter lens should conform
to ANSI Z87. I standards.
2.b.  Use  suitable  clothing  including  gloves  made  from  durable
flame-resistant material to protect your skin and that of your
helpers from the arc rays.
2.c.  Protect  other  nearby  personnel  with  suitable  non-flammable
screening and/or warn them not to watch the arc nor expose
themselves to the arc rays or to hot spatter or metal.
ELECTRIC  SHOCK  can
kill.
1.a.  The  electrode  and  work  (or  ground)  circuits
are electrically “hot” when the power source is on.
Do not touch these “hot” parts with your bare skin
or  wet  clothing.  Wear  dry,  hole-free  gloves  to
insulate hands.
1.b.  When  the  power  source  is  operating  voltages  in  excess  of
250 volts are produced. This creates the potential for serious
electrical shock - potentially even fatal.
1.c. Insulate yourself from work and ground using dry insulation.
When cutting or gouging in damp locations, on metal frame-
work such as floors, gratings or scaffolds and when in posi-
tions  such  as  sitting  or  lying,  make  certain  the  insulation  is
large enough to cover your full area of physical contact with
work and ground.
1.d. Always be sure the work cable makes a good electrical con-
nection with the metal being cut or gouged. The connection
should  be  as  close  as  possible  to  the  area  being  cut  or
gouged.
1.e. Ground the work or metal to be cut or gouged to a good elec-
trical (earth) ground.
1.f.  Maintain  the  plasma  torch,  cable  and  work  clamp  in  good,
safe operating condition. Replace damaged insulation.
1.g.  Never  dip  the  torch  in  water  for  cooling  or  plasma  cut  or
gouge in or under water.
1.h.  When  working  above  floor  level,  protect  yourself  from  a  fall
should you get a shock.
1.i. Operate the pilot arc with caution. The pilot arc is capable of
burning the operator, others or even piercing safety clothing.
1.j. Also see Items 4c and 6.
WARNING
PLASMA CUTTING or GOUGING can be hazardous.
FUMES AND GASES
can be dangerous.
3.a.  Plasma  cutting  or  gouging  may  produce
fumes  and  gases  hazardous  to  health.  Avoid
breathing these fumes and gases. When cutting 
or  gouging,  keep  your  head  out  of  the  fumes.  Use  enough
ventilation  and/or  exhaust  at  the  arc  to  keep  fumes  and
gases away from the breathing zone. When plasma cutting
or  gouging  on  lead  or  cadmium  plated  steel  and  other
metals  or  coatings  which  produce  highly  toxic  fumes,
keep exposure as low as possible and within applicable
OSHA PEL and ACGIH TLV limits using local exhaust or
mechanical  ventilation.  In  confined  spaces  or  in  some
circumstances,  outdoors,  a  respirator  may  be  required.
Additional  precautions  are  also  required  when  welding
on galvanized steel.
3. b. The  operation  of  plasma  cutting  or  gouging  fume  control
equipment is affected by various factors including proper use
and positioning of the equipment, maintenance of the equip-
ment  and  the  specific  procedure  and  application  involved.
Worker  exposure  level  should  be  checked  upon  installation
and periodically thereafter to be certain it is within applicable
OSHA PEL and ACGIH TLV limits.
3.c. Do not use plasma cutting or gouging equipment in locations
near  chlorinated  hydrocarbon  vapors  coming  from  degreas-
ing, cleaning or spraying operations. The heat and rays of the
arc can react with solvent vapors to form phosgene, a highly
toxic gas, and other irritating products.
3.d. Gases used for plasma cutting and gouging can displace air
and  cause  injury  or  death.  Always  use  enough  ventilation,
especially in confined areas, to insure breathing air is safe.
3.e. Read and understand the manufacturer’s instructions for this
equipment and follow your employer’s safety practices.