Справочник Пользователя для Lincoln Electric SVM149-A
PRO-CUT 25
TROUBLESHOOTING & REPAIR
F-6
F-6
Observe Safety Guidelines
TROUBLESHOOTING GUIDE
detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
COURSE OF ACTION
FUNCTION PROBLEMS
The cutting arc starts but sputters
badly.
badly.
1. Make sure the operating proce-
2. Make sure the work clamp is
connected tightly to the work
piece.
piece.
3.
Make sure the torch consum-
able parts are in place and in
good condition. Replace if
necessary.
able parts are in place and in
good condition. Replace if
necessary.
4.
Make sure the air pressure is
set at 65psi.
set at 65psi.
5.
Make sure the air supply is not
contaminated with oil or
excessive water.
contaminated with oil or
excessive water.
1. Check all connectors and
wires for loose or faulty con-
nections. See Wiring Diagram.
nections. See Wiring Diagram.
2. Perform the Torch Continuity
3. Perform the Main Inverter
4.
The control board may be
faulty. Replace.
faulty. Replace.
5. Use the correct extension cord.
See the instruction manual.
The pilot arc is normal, but the arc
will not transfer to the work piece.
will not transfer to the work piece.
1.
2. Make sure the work clamp is
connected tightly to the work
piece.
piece.
3. The work piece must be electri-
cally conductive material, and
the work clamp must make a
good electrical connection with
the work piece.
the work clamp must make a
good electrical connection with
the work piece.
4. Do not use a drag cup. Not
recommended for Pro-Cut 25
use.
use.
1. Check all connectors and
wires for loose or faulty con-
nections. See Wiring Diagram.
nections. See Wiring Diagram.
3.
The control board may be
faulty. Replace.
faulty. Replace.
Trigger or purge is activated brief
air flow then the safety light illumi-
nates.
air flow then the safety light illumi-
nates.
1. The Control Board is defective.
Replace.
Poor performance of pilot arc or
cutting. Poor consumable life.
cutting. Poor consumable life.
1. Check pressure switch to be
functioning correctly
(opening/closing) at its correct
pressure.
(opening/closing) at its correct
pressure.
2. Check pressure gauge to be
correct in its reading.
3. Check for recommended flow
rate coming from the torch end
with a flow meter.
with a flow meter.
1. Try increasing or decreasing the
air pressure to see if conditions
improve.
improve.
2. Replace regulator or pressure
switch may be required.
3. Screen in air line at inlet to air
solenoid may be clogged.
Clean. (no screen before 7/1/02)
Clean. (no screen before 7/1/02)
4. Ensure that air is clean and dry
External filters may be used.