Справочник Пользователя для Lincoln Electric IM 513-B

Скачать
Страница из 44
– 20 –
OPERATING INSTRUCTIONS
Additional Safety Precautions
The  output  terminals  are  energized  when  the
engine is running.  The CV output will be de-ener-
gized only if WFM mode switch is in remote posi-
tion.
WIRE FEED MODULE OPERATION
Output
For constant voltage welding, place the CC/CV mode
switch in the CV position.  Connect the wire feeder to
the CV negative output terminal and connect the work
to the positive standard output terminal.  For electrode
positive, reverse the output leads.  The negative stan-
dard  output  terminal  is  not  used  for  CV  welding  of
either polarity.  Refer to diagrams section to determine
the  correct  connection  to  the  remote  control  recepta-
cle.  
When  the  WFM  is  in  the  “CV”  mode,  the  maximum
auxiliary  power  will  be  reduced  by  25%.    To  obtain
maximum auxiliary output, place the CC/CV switch in
the CC position.
If the current rating of the welder is exceeded, a ther-
mostat will reduce the output voltage to approximately
5 volts.  The thermostat will reset automatically as the
machine cools.  If the thermostat trips, lower the wire
feed speed and output voltage or reduce Duty Cycle.
Controls
The output voltage is set with the voltage control dial
mounted  on  the  control  panel.    Set  the  “Current
Range Selector" to the “190-120” position for optimum
welding characteristics.  Changing the "Current Range
Selector”  affects  arc  characteristics.    Setting  the
“Current  Range  Selector”  one  position  to  the  right  of
the  "190-120”  position  will  give  a  softer  arc.    If  this
switch is placed one position to the left from the "190-
120”  set  point,  the  machine  will  produce  a  crisp  arc
characteristic.    The  setting  of  the  “Fine  Current
Adjustment"  has  no  effect  on  the  operation  in  “CV”
mode.
For Coarse Current Control on the SAE-300 see oper-
ator manual.
Recommended Processes
Refer to latest Lincoln Bulletins on (Gas Metal Arc
Welding)  and  (Innershield  Welding)  with  the  fol-
lowing electrodes:
.030”
Super Arc L-50, 56 with C-25 or CO
2
Gas
.035”
Super Arc L-50, 56 with C-25 or CO
2
Gas
.045”
Super Arc L-50, 56 with C-25 or CO
2
Gas
.068”
NR-203MP
5/64”
NR-203MP
5/64”
NR-207
5/64”
NR-203Nil%
MAINTENANCE
Engine Speed Adjustments
Any  increase  in  the  engine  RPM  by  changing  the
governor setting or overriding the throttle linkage
will  cause  an  increase  in  the  A.C.  auxiliary  volt-
age.  If this voltage goes above 140 volts, the con-
trol  circuits  of  the  WFM  and  wire  feeders  will  be
damaged.    The  engine  governor  setting  is  pre-set
at the factory -- do not adjust above RPM specifi-
cations listed in the engine welder operating man-
ual.
WARNING
CAUTION
TROUBLESHOOTING CHART
Have qualified personnel do the maintenance and
troubleshooting work.  Turn the engine off before
beginning to troubleshoot.
WARNING