PRECISION TIG 185
TROUBLESHOOTING & REPAIR
F-8
F-8
TROUBLESHOOTING GUIDE
Observe Safety Guidelines
detailed in the beginning of this manual.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
1-888-935-3877.
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
1-888-935-3877.
TIG MODE PROBLEMS
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
Machine output is intermittently lost.
Gas flow and high frequency are
also interrupted.
Gas flow and high frequency are
also interrupted.
1. The problem may be caused by
high frequency interference.
Make sure that the machine is
grounded properly according to
the installation instructions. If
there are other high frequency
sources in the area, make certain
that they are grounded properly.
Make sure that the machine is
grounded properly according to
the installation instructions. If
there are other high frequency
sources in the area, make certain
that they are grounded properly.
2. Make sure the Amptrol is operat-
ing properly.
3. Check to make sure that the
in the Installation section of this
manual.
manual.
1. Check for loose or faulty connec-
tion on the leads between the
remote receptacle and plug J5
on the control board. See wiring
diagram.
remote receptacle and plug J5
on the control board. See wiring
diagram.
2. Check the plugs on the control
board for loose connections.
3. The control board may be faulty.