Справочник Пользователя для Pelco C1498M-B

Скачать
Страница из 20
Pelco Manual C1498M-B (7/99)
9
225
ON
OFF
OFF
OFF
OFF
ON
ON
ON
226
OFF
ON
OFF
OFF
OFF
ON
ON
ON
227
ON
ON
OFF
OFF
OFF
ON
ON
ON
228
OFF
OFF
ON
OFF
OFF
ON
ON
ON
229
ON
OFF
ON
OFF
OFF
ON
ON
ON
230
OFF
ON
ON
OFF
OFF
ON
ON
ON
231
ON
ON
ON
OFF
OFF
ON
ON
ON
232
OFF
OFF
OFF
ON
OFF
ON
ON
ON
233
ON
OFF
OFF
ON
OFF
ON
ON
ON
234
OFF
ON
OFF
ON
OFF
ON
ON
ON
235
ON
ON
OFF
ON
OFF
ON
ON
ON
236
OFF
OFF
ON
ON
OFF
ON
ON
ON
237
ON
OFF
ON
ON
OFF
ON
ON
ON
238
OFF
ON
ON
ON
OFF
ON
ON
ON
239
ON
ON
ON
ON
OFF
ON
ON
ON
240
OFF
OFF
OFF
OFF
ON
ON
ON
ON
241
ON
OFF
OFF
OFF
ON
ON
ON
ON
242
OFF
ON
OFF
OFF
ON
ON
ON
ON
243
ON
ON
OFF
OFF
ON
ON
ON
ON
244
OFF
OFF
ON
OFF
ON
ON
ON
ON
245
ON
OFF
ON
OFF
ON
ON
ON
ON
246
OFF
ON
ON
OFF
ON
ON
ON
ON
247
ON
ON
ON
OFF
ON
ON
ON
ON
248
OFF
OFF
OFF
ON
ON
ON
ON
ON
249
ON
OFF
OFF
ON
ON
ON
ON
ON
250
OFF
ON
OFF
ON
ON
ON
ON
ON
251
ON
ON
OFF
ON
ON
ON
ON
ON
252
OFF
OFF
ON
ON
ON
ON
ON
ON
253
ON
OFF
ON
ON
ON
ON
ON
ON
254
OFF
ON
ON
ON
ON
ON
ON
ON
Receiver Address
Switch Setting
SW2-1
SW2-2
SW2-3
SW2-4
SW2-5
SW2-6
SW2-7
SW2-8
Table C.  Switch Settings for SW2 – D-Type Control (Continued)
NOTE:
For Coaxitron
®
 controls, SW2 is not used; set all switches OFF.
For P-type control systems, refer to Table B.
OPERATION
The red LED in the back box interconnect door lights when power is turned on, and the fan
exhausts heat from inside the back box when the dome drive is installed. If you have an
outdoor pendant model with a heater, heater elements in the back box turn on at 70
°
F
(21
°
C) and off at 85
°
F (29
°
C). The heater element in the lower dome turns on at 40
°
F (4
°
C)
and off at 60
°
F (16
°
C). The interconnect door fan and heater fans in the outdoor back box
operate continuously.
POWER-UP DISPLAY
When the dome is powered up or reset, the monitor displays the selected protocol, revision
number, and other information, which remains until the dome moves. The information
displayed depends on the selected protocol and the choice made on the menu for
selectable power-up mode. As a default, the dome goes to a random position.
The control system protocol (C, D, or P) appears. C is for Pelco’s Coaxitron
®
 control
system. D-type control is RS-422 compatible with Pelco’s CM6700, MPT9500, and CM8500
controllers or with American Dynamics control systems using the AD2083 Translator. P-type
control is RS-422 compatible with Pelco’s CM6700 and CM9750/CM9760 control systems.
For D and P protocols, the device address, baud rate, parity (N), number of data bits (8), and
number of stop bits (1) appears. For D protocol, “32 presets” appears if the 32-preset mode is
selected (SW1-7 ON). “CM9500 mode” appears if CM9500 mode is selected (SW1-8 ON).
NOTE:
 The dome will stop
operating if voltage at the
dome drops below 18 VAC.
It will turn back on and go
through its start-up routine
when the voltage exceeds
18 VAC.