Справочник Пользователя для Mitsubishi Electronics E70
4 Connection
MITSUBISHI CNC
96
4.3.4.3 Wiring for Source Type Output (FCU7-DX621/DX711/DX721/DX731)
(Note 1) Connect +24V to either or both of the flat connector 1B, 2B (24VDC). (*1)
(Note 2) Connect +24V (GND) to the flat connector 3A, 3B, 4A, 4B (24VDC). (*1)
Decide the number of 24VDCs to wire with regard to the total amount of each connector's maximum output
current and the voltage drop by the cables. The rated current is 1A per connector pin.
(Note 3) Connect 0V (GND) to the flat connector 1A, 2A (GND). (*2)
(Note 4) When large current flows due to small amount of connected load, fuse may be blown out or 24V power supply
voltage may drop. In order to secure the appropriate current value, watch the connected load.
2B
20B
19B
18B
17B
16B
19B
18B
17B
16B
15B
14B
13B
12B
11B
10B
14B
13B
12B
11B
10B
9B
8B
8B
7B
6B
5B
6B
5B
CG32 (CG34,CG36)
3A
3B
3B
GND
1A
2A
2A
GND
1B
4A
4B
GND
࣭
࣭
࣭
࣭
࣭
࣭
࣭
࣭
࣭
࣭
࣭
࣭
࣭
࣭
࣭
࣭
࣭
࣭
࣭
࣭
Y2 00
Y2 01
Y2 02
Y2 03
Y2 01
Y2 02
Y2 03
Y2 04
Y2 05
Y2 06
Y2 05
Y2 06
Y2 07
Y2 08
Y2 08
Y2 09
Y2 0A
Y2 0B
Y2 0C
Y2 0A
Y2 0B
Y2 0C
Y2 0D
Y2 0E
Y2 0F
Y2 10
Y2 11
Y2 12
Y2 0E
Y2 0F
Y2 10
Y2 11
Y2 12
Y2 13
Y2 14
Y2 15
Y2 16
Y2 17
Y2 18
Y2 14
Y2 15
Y2 16
Y2 17
Y2 18
Y2 19
Y2 1A
Y2 1B
Y2 1C
Y2 1D
Y2 1E
Y2 1F
Y2 1A
Y2 1B
Y2 1C
Y2 1D
Y2 1E
Y2 1F
20A
19A
18A
17A
16A
15A
14A
13A
12A
18A
17A
16A
15A
14A
13A
12A
11A
10A
10A
9A
8A
7A
6A
5A
8A
7A
6A
5A
PL
PL
PL
RA
RA
PL
PL
PL
RA
PL
PL
:
:
:
Relay
Pilot lamp
Pilot lamp
24VDC
24VDC
24VDC
24VDC
24VDC
24VDC
24VDC
24VDC
24VDC
Operation panel I/O unit
(Card name : HN331/HN351/HN371/HN372)
Machine side
*1 Additional wiring
*2 Additional wiring
Output device (Connection example)
24VDC