Справочник Пользователя для Mitsubishi Electronics E70

Скачать
Страница из 214
E70 Series Connection Manual
Appendix 1.14 F034/F035 Cable
131
Appendix 1.14 F034/F035 Cable
Max. cable length:  15m (the maximum length of the cable when connected to the control unit via other 
units)
Application: RS232C I/F cable (for control unit)
(Note 1) Fold the cable shield over the sheath, and wrap copper foil tape over it. Connect the wound copper foil 
tape to GND plate of the connector. 
(Note 2) Signal names in parentheses "( )" are generally used. 
(Note 3) Connect to the serial communication connector of the control unit.  Use G031/G032 cable when 
connecting to the serial communication connector of the display unit. 
[SIO]
Connector: 10120-3000VE 
Case:  10320-52F0-008 
Recommended manufacturer: 3M
Wire material: UL1061-2464 
AWG24×12P 
Recommended manufacturer: Oki 
Electric Cable
[1ch][2ch]
Connector: CDB-25S 
Contact: CD-SC-111×9 
Lock nut: HD-LNA×2 
Recommended manufacturer: 
Hirose Electric
Cable name
1ch
2ch
F034 cable
F035 cable
○ : Usable channel
1ch
SIO
2ch
SIO
1ch
FG
12
2
13
3
14
4
16
6
1
17
7
18
8
19
9
20
10
11
SD1(TXD1)
RD1(RXD1)
RS1(RTS1)
CS1(CTS1)
ER1(DTR1)
DR1(DSR1)
Reserved
Reserved
0V
SD2(TXD2)
RD2(RXD2)
RS2(RTS2)
CS2(CTS2)
ER2(DTR2)
DR2(DSR2)
Reserved
Reserved
0V
2
3
4
5
20
6
8
9
7
2
3
4
5
20
6
8
9
7
2ch