Справочник Пользователя для Mitsubishi Electronics E70

Скачать
Страница из 214
Appendix 2 EMC Installation Guidelines
MITSUBISHI CNC
166
Appendix 2.5.2 Shield Treatment of Cables
Use shielded cables for the cables wired outside the panel.  
Use a shield clamp within 10cm of the lead-out port from the panel. (Refer to "EMC Countermeasure Parts:  Shield 
Clamp Fitting".)
(1)
DC power supply cable [F110/F070 cable]
Use a shield clamp within 10cm from the panel's inlet/outlet. 
When using a ferrite core, install it on both ends of the connected units. 
Always install a ferrite core (Refer to "EMC Countermeasure Parts: Ferrite Core".) on the general-purpose 
stabilized power supply.  The ferrite core may not be required depending on the selected power supply. 
(2)
Remote I/O cable [FCUA-R211 cable]
-
Use a shield clamp within 10cm from the panel's inlet/outlet. 
-
 When using a ferrite core, install it on both ends of the connected units. 
PD25
Operation panel
Control panel
Display unit
F110 cable
Shield clamp
General-purpose 
stabilized power supply
F070 cable
Ferrite core
Operation panel 
I/O unit
Control panel
Control panel
Control unit
Shield clamp
Ferrite core
Remote I/O unit
FCUA-R211 cable