Справочник Пользователя для Mitsubishi Electronics SDP-ECO 1630 III

Скачать
Страница из 83
Chapter 2   Names of Machine Components and Parts
- 17 -
2.2 Operation panel
(1)
Display panel
The operation mode, error messages, and setting values for various
parameters are displayed on this panel.
(2)
Power ON/OFF key
The power ON/OFF key is used to turn OFF the power after a processor
cleaning operation.  This key is used for the usual ON/OFF operation.
(3)
ON LINE lamp
The ON LINE lamp is lit during transmission or standby status between
the SDP-Eco 1630 III and host computer.
(4)
LOADED lamp
The LOADED lamp lights when a film is loaded and at its exposure
position.
(5)
Stop key (Reset)
The STOP key is used to interrupt the exposure of a plate.  If the exposure
is interrupted, the plate will be cut and discharged.  This key is also used
to cancel errors and to turn OFF the error buzzer.
(6)
key
The 
key is used to switch the user's mode between remote and local.
Also it returns the menu to the upper level.
(7)
Select key
The SELECT key is used to move the cursor or change parameters.
(8)
key
The 
key is used to enter parameters or to execute various
commands.
ENT.
ENT.
MENU
MENU
(2)
(1)
(3)
(4)
(5)
(6)
(7)
(8)