Справочник Пользователя для Zebra Technologies 11380100000

Скачать
Страница из 188
Routine Maintenance
Cleaning Schedule and Procedures
128
P1009874-003
Xi4™/RXi4™ User Guide
4/30/13
Clean the Cutter
If the cutter is not cutting the labels cleanly or if it jams with labels, clean the cutter.
To clean the cutter, complete these steps:
1.
2.
Using the swab from the Preventive Maintenance Kit (part number 47362), clean the 
stationary cutter blade. In place of the Preventive Maintenance Kit, you may use a clean 
swab dipped in a solution of isopropyl alcohol (minimum 90%) and deionized water 
(maximum 10%). Allow the solvent to evaporate.
3.
If cleaning does not remove label fragments and adhesive, contact an authorized service 
technician.
4.
Reconnect the data cables and AC power cord, and turn on (l) the printer.
Caution • 
The cutter blade is sharp. Do not touch or rub the blade with your fingers.
Caution • 
Turn off (
O
) the printer and disconnect it from the power source before 
performing the following procedure.
Turn off (O) the printer, and disconnect the AC power cord and all data cables.