Справочник Пользователя для IBM 220

Скачать
Страница из 148
 2
IBM® xSeries 220  User’s Reference
 
 
Features and specifications
Table 1 provides a summary of the features and specifications of your xSeries 220 
server. 
*KB equals approximately 1000 bytes. MB equals approximately 1000000 bytes. GB 
equals approximately 1000000000 bytes. 
Microprocessor:
 
Intel® Pentium® III 
microprocessor with MMX™ 
technology and SIMD 
extensions
256 KB* ECC, level-2 cache 
(min.)
133 MHz front-side bus (FSB)
Support for up to two 
microprocessors
 Memory: 
Standard: 128 MB*
Maximum: 4 GB*
Type: 133 MHz, ECC, SDRAM, 
registered DIMMs 
Slots: 4 dual in-line 
 Drives standard: 
Diskette: 1.44 MB
CD-ROM: 48X IDE
Supports hot-swap SCSI hard 
disk drives (some models)
 Expansion bays: 
Two 5.25-in. bays (one CD-ROM 
drive installed)
Two 3.5-in. bays (one diskette 
drive installed)
Three 3.5-in. slim bays available 
in drive cage (some models 
have a hard disk drive installed)
PCI expansion slots:
 
Three 33 MHz/64-bit
Two 33 MHz/32-bit
Power supply:
One 330 watt autosensing (115-230 V 
ac) 
Video:
 
S3 video controller (integrated 
on system board)
Compatible with SVGA and 
VGA
8 MB SDRAM video memory
 Size: 
Height: 470 mm (18.5 in.)
Depth: 508 mm (20 in.)
Width: 165 mm (6.5 in.)
Weight: approximately 19.5 Kg 
(43 lb.) when fully configured 
or 15.9 Kg (35 lb.) minimum
 Integrated functions: 
Ultra160 SCSI low voltage 
differential (LVD) controller 
One 10BASE-T/100BASE-TX 
Intel Ethernet controller on the 
system board
Two serial ports
Parallel port
Two Universal Serial Bus 
(USB) ports
Keyboard port
Mouse port
IDE controller port
Video port
 Acoustical noise emissions: 
Sound power, idling: 5.1 bel 
maximum
Sound power, operating: 5.3 
bel maximum
Environment:
 
Air temperature:  
— Server on: 10
°
 to 35
°
 C (50.0
°
 
to 95.0
°
 F). Altitude: 0 to 914 
m (2998.7 ft) 
— Server on: 10
°
 to 32
°
 C (50.0
°
 
to 89.6
°
 F). Altitude: 914 m 
(2998.7 ft) to 2133 m (6998.0 
ft)
— Server off: 10
°
 to 43
°
 C (50.0
°
 
to 109.4
°
 F). Maximum 
altitude: 2133 m (6998.0 ft) 
Humidity:  
— Server on: 8% to 80%
— Server off: 8% to 80%
 Heat output:
Approximate heat output in British 
thermal units (Btu) per hour
Minimum configuration: 341 Btu 
(100 watts)
Maximum configuration: 1604 
Btu (470 watts)
Electrical input:
 
Sine-wave input (50-60 Hz) 
required
Input voltage low range:  
— Minimum: 100 V ac
— Maximum: 127 V ac 
Input voltage high range:  
— Minimum: 200 V ac
— Maximum: 240 V ac
Input kilovolt-amperes (kVA), 
approximately:  
— Minimum: 0.08 kVA
— Maximum: 0.52 kVA
Table 1. Features and specifications