9. You will be asked to choose the language you wish to use. Select your
language (0-7) and press Enter to accept your choice. You will be prompted to
remove the diskette and press Enter to restart the system. Remove the flash
diskette from the diskette drive.
10. Power off the NAS 200.
11. Remove the jumper on the boot-block jumper block, or move it to pins 1 and 2
to return to normal startup mode.
12. Restart the NAS 200. It should start up normally.
Figure 2 shows the location of the boot block jumper on the system board.
Replacing the battery
IBM has designed this product with your safety in mind. The lithium battery must be
handled correctly to avoid possible danger. If you replace the battery, you must
adhere to the following instructions.
Note: In the U.S., call 1-800-IBM-4333 for information about battery disposal.
If you replace the original lithium battery with a heavy-metal battery or a battery with
heavy-metal components, be aware of the following environmental consideration.
Batteries and accumulators that contain heavy metals must not be disposed of with
normal domestic waste. They will be taken back free of charge by the manufacturer,
distributor, or representative, to be recycled or disposed of in a proper manner.
To order replacement batteries, call 1-800-772-2227 within the United States, and
1-800-465-7999 or 1-800-465-6666 within Canada. Outside the U.S. and Canada,
call your IBM reseller or IBM marketing representative.
Note: After you replace the battery, you must reconfigure your appliance and reset
the system date and time.
1  2  3  4  5  6  7  8
SW1
Flash boot block
recovery jumper (J16)
System board
Switch block (SW1)
ON
Figure 2. Boot block jumper location