6.2  Troubleshooting list 
 
A lot of malfunctions can be traced back to incorrect or loose cable connection. So 
please make sure that all plug connections are correct and secured. 
 
Fault Possible 
cause 
Remark 
voltage supply not in 
order 
check plug-in connection of power 
supply 
LED on Touch / Screen 
Commander remains dark 
computer switched off 
switch on the computer 
LED on Touch / Screen 
Commander lights up red 
and no picture appears 
VGA cable is not 
correctly connected 
check cable connection of VGA 
connection 
choice of display 
resolution is wrong 
check for correct display resolution 
it should be 1024x768 or less 
The display shows only 
part of the picture or the 
picture is distorted 
display adjustment 
insufficient 
see notice to adjustment of in 
chapter 3.3 
LCD shows indistinct 
vertical stripes 
display ("HORIZONTAL 
SIZE") is insufficiently 
set 
set horizontal size of picture in 
menu IMAGE POSITION of 
OSD(see chapter 3.3.2) 
LCD shows fine horizontal 
stripes 
display ("PHASE") is 
not correctly adjusted 
adjust PHASE in menu BASIC-
SETTINGS of OSD (see chapter 
3.3.1) 
Touch cannot be calibrated 
under the operating 
systems of Windows, 
button "calibrate" is 
deactivated  
cable connection 
incorrect 
check serial connection, restart 
computer 
Vertical streaks in LCD 
image 
Display “Clock” or 
“Horizontal Position” 
improperly set  
Set horizontal position and size of 
picture in menu “H-Position”and 
“Clock” of OSD (see chapter 3.3.2) 
Calibrating program states 
error when called up 
touchscreen driver not 
correctly installed 
Set the driver again with SETUP or 
with button setup in the calibrating 
program. Here the serial connection 
should be correctly entered and the 
correct controller should be 
selected. Check the serial cable 
connection 
 
 6.3 Additional help 
If you have problems with the connection and the installation of the Preh Touch / Screen 