Справочник Пользователя для Marathon Computer AACC 2000

Скачать
Страница из 103
Marathon Monitors Inc.
AACC 2000 Carbon                                                                       Nov.  1, 1997
8
Technical Specification
Environmental ratings
Panel sealing:
Instruments are intended to be panel mounted. The
rating of panel sealing is IP65, (EN 60529), or 4X, (NEMA
250).
Operating temperature:
0 to 55
o
C.  Ensure the enclosure provides adequate
ventilation.
Relative humidity:
5 to 95%, non condensing.
Atmosphere:
The instrument is not suitable for use above 2000m
or in explosive or corrosive atmospheres.
Equipment ratings
Supply voltage:
100 to 240Vac -15%, +10%, or optionally:
Supply frequency:
48 to 62Hz.
Power consumption:
15 Watts maximum.
Relay 2-pin (isolated):
Maximum: 264Vac, 2A resistive. Minimum: 12Vdc, 100mA.
Relay changeover (isolated): Maximum: 264Vac, 2A resistive. Minimum: 6Vdc, 1mA.
Triac outputs (isolated):
30 to 264Vac. Maximum current: 1A resistive.
Leakage current:
The leakage current through triac and relay contact
suppression components is less than 2mA at 264Vac, 50Hz.
Over current protection:
External over current protection devices are required that
match the wiring of the installation. A minimum of 0.5mm
2
 or
16awg wire is recommended. Use independent fuses for the
instrument supply and each relay or triac output. Suitable
fuses are T type, (EN 60127 time-lag type) as follows;
Instrument supply: 85 to 264Vac, 2A, (T).
Relay outputs: 2A (T). Triac outputs: 1A (T).
Low level i/o:
All input and output connections other than triac and relay are
intended for low level signals less than 42V.
Single logic output:
18V at 24mA. (Non-isolated.)
DC output (Isolated):
0 to 20mA (600
Ω
 max), 0 to 10V (500
Ω
 min).
DC output (Non isolated):
0 to 20mA (600
Ω
 max), 0 to 10V (500
Ω
 min).
Fixed digital inputs:
Contact closure. (Non isolated.)
Triple contact input:
Contact closure. (Isolated.)
Triple logic input:
11 to 30Vdc. (Isolated.)
DC or 2
nd
 PV input:
As main input plus 0-1.6Vdc, Impedance, >100M
Ω
.
(Isolated.)
Potentiometer input:
0.5V excitation, 100
Ω
 to 1.5k
Ω
 Potentiometer. (Isolated.)
Transmitter supply:
24Vdc at 20mA. (isolated.)
Strain gauge supply:
10Vdc. Minimum bridge resistance 300
Ω
. (Isolated.)
Digital Communications:
EIA-232, 2-wire EIA-485 or 4-wire EIA-485 (All isolated).