Справочник Пользователя для Seagate ST980310AS
26
Momentus 5400.5 SATA Product Manual, Rev. B
4.3.1
Identify Device command
The Identify Device command (command code EC
H
) transfers information about the drive to the host following
power up. The data is organized as a single 512-byte block of data, whose contents are shown in the table on
page 27. All reserved bits or words should be set to zero. Parameters listed with an “x” are drive-specific or
vary with the state of the drive.
page 27. All reserved bits or words should be set to zero. Parameters listed with an “x” are drive-specific or
vary with the state of the drive.
The following commands contain drive-specific features that may not be included in the Serial ATA specifica-
tion.
tion.
Word
Description
Value
0
Configuration information:
• Bit 15: 0 = ATA; 1 = ATAPI
• Bit 7: removable media
• Bit 6: removable controller
• Bit 0: reserved
0C5A
H
1
Number of logical cylinders
16,383
2
ATA-reserved
0000
H
3
Number of logical heads
16
4
Retired
0000
H
5
Retired
0000
H
6
Number of logical sectors per logical track: 63
003F
H
7–9
Retired
0000
H
10–19
Serial number: (20 ASCII characters, 0000
H
= none)
ASCII
20
Retired
0000
H
21
Retired
0400
H
22
Obsolete
0000
H
23–26
Firmware revision (8 ASCII character string, padded with
blanks to end of string)
blanks to end of string)
x.xx
27–46
Drive model number: (40 ASCII characters, padded with
blanks to end of string)
blanks to end of string)
ST9320320AS
ST9250320AS
ST9200321AS
ST9160310AS
ST9160310ASG
ST9120310AS
ST9120310ASG
ST980310AS
ST980310ASG
47
(Bits 7–0) Maximum sectors per interrupt on Read multiple
and Write multiple (16)
and Write multiple (16)
8010
H
48
Reserved
0000
H
49
Standard Standby timer, IORDY supported and may be dis-
abled
abled
2F00
H
50
ATA-reserved
0000
H
51
PIO data-transfer cycle timing mode
0200
H
52
Retired
0200
H
53
Words 54–58, 64–70 and 88 are valid
0007
H
54
Number of current logical cylinders
xxxx
H