Справочник Пользователя для Seagate ST31000640FC

Скачать
Страница из 84
Barracuda ES.2 FC Product Manual, Rev. B
23
6.0
Physical/electrical specifications
This section provides information relating to the physical and electrical characteristics of the drive.
6.1
AC power requirements 
None.
6.2
DC power requirements 
The voltage and current requirements for a single drive are shown below. Values indicated apply at the drive 
connector. Notes are shown following table 2.     
[1]
Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these val-
ues. Power supply at nominal voltage. N (number of drives tested) = 6, 35 Degrees C ambient.
[2]
For +12 V, a –10% tolerance is allowed during initial spindle start but must return to ±5% before reaching 
10,000 RPM. The ±5% must be maintained after the drive signifies that its power-up sequence has been 
completed and that the drive is able to accept selection by the host initiator.
[3]
See +12V current profiles in Figure 1.
[4]
This condition occurs when the Motor Start option is enabled and the drive has not yet received a Start 
Motor command. 
[5]
See paragraph 6.2.1, "Conducted noise immunity." Specified voltage tolerance includes ripple, noise, and 
transient response.
[6]
During idle, the drive heads are relocated every 60 seconds to a random location within the band from 
Table 2:
DC power requirements
4 Gbit
Notes
(Amps)
(Amps)
Voltage
+5V
+12V [2]
Regulation
[5]
±5%
±5% [2]
Avg idle current DCX
[1] [6]
0.75
0.50
Maximum starting current
(peak DC) DC
3
σ
[3]
1.00
2.00
(peak AC) AC
3
σ
[3]
1.15
3.23
Delayed motor start (max) DC
3
σ
0.65
0.04
Peak operating current:
     Typical DCX
[1]
0.69
0.77
     Maximum DC
3
σ
[1]
0.71
0.82
     Maximum (peak) DC
3
σ
1.13
1.67