Diagnostic Utilities
96154 • Revision K
Chapter 6 Troubleshooting and Diagnostics 105
Entire library audit. The robot visits all cartridge slots (including the CAPs and 
drives), catalogs the VOLIDs and locations, and updates the HBC cartridge 
database. This audit is a background process and so does not interrupt online 
library operations. View the Cartridge Summary Report for the latest cartridge 
locations and VOLIDs.
Note – 
The estimated time for a physical audit of an entire library is from less than 10 
minutes for a 1,448 cartridge library to 45 minutes for 6,632 cartridge library.
Specific range audit. the robot visits only a specific range of cartridge slots 
(including caps and drives) and updates the HBC database. The audit information 
is displayed on the console while the audit is being performed.
2.  Verified audit. Available through the StreamLine Library Console, this audit 
validates the status of a specific cartridge slot (or range of slots). If a cartridge in a 
slot has a status of “false,” the VOLID is audited and the database is updated. The 
audit information is displayed on the console while the audit is being performed.
3.  Virtual audit. Available through the StreamLine Library Console, this audit displays 
the cartridge database.
Performing Library Self-test
The self-test is minimal functional test performed after the library is installed and also 
at periodic intervals during library operations to help diagnose basic problems with 
library and the associated devices (drives, robots, elevators, and CAPs). 
The self-test checks the communication paths between the main library controller 
(HBC) and all drives, robots, elevators, and CAPs. The utility also performs several 
motion tests to check the health of the robots, elevators, and CAPs. Finally, a full audit 
of the library is performed, followed by drive mounts and dismounts.
Moving Cartridges
Using the move utility, you can move a cartridge from one location (source) to another 
(destination) within a library. Examples: (1) you might decide to group cartridges by 
data type or to move them closer to their assigned drive. (2) to replace a cleaning 
cartridge that has expired
move the cartridge to a CAP slot and then perform an 
eject; enter the new cleaning cartridges into a CAP slot and move the cartridge from the 
CAP slot to a reserved slot. 
Before moving any cartridge, it might be helpful to generate a cartridge summary 
report that shows the contents of slots in the library. This report will help you 
determine which slots are available for use and which cartridges might have to be 
moved to obtain their slot.