Library Complex
96154 • Revision K
Chapter 1 Introduction 19
The system PDU, connected directly to the branch circuit, provides AC power to 
three DC power grids and the electronics control module. 
The N+1 PDU supplies added +48 VDC load sharing power to each of the three DC 
power grids and an extra AC-to-DC power supply for the electronics control 
module. 
The base power configuration provides power to the:
Tape drive power supplies
Robotic rail power supplies
Customer Interface Module power supplies
Touch screen operator control panel
Electronics control module power supplies
Note – 
The base power configuration does not offer redundant AC power.
2N Power Configuration
The 2N power configuration contains the base power configuration (PDU 1) and a 
second PDU, PDU number 2. 
This configuration provides power to the same components as N+1, plus power for:
Optional, redundant load sharing power supplies
Two additional accessory racks for customer components
Redundant controller cards
Note – 
The 2N PDU is required for the 2N drive power, 2N robotic power, and also for 
the additional rack installed.
Library Complex
A library complex is created by connecting two or more SL8500 libraries together with 
Pass-thru Ports (PTPs).
The maximum size library complex possible consists of either:
32 libraries for Host Software Component (HSC) systems, connected through PTPs, 
containing over 320,000 cartridge slots and 2,048 tape drives.
31 libraries for Automated Cartridge System Library Software (ACSLS) connection, 
connected through PTPs, containing over 320,000 cartridge slots and 1,984 tape 
drives.
Note – 
A library complex with functional pass-thru ports (PTPs) cannot be partitioned. 
All PTPs must be disabled before partitioning can be enabled. See 
 for details.