Configuring Library Partitions
34 StreamLine™ SL8500 Modular Library System User's Guide • March 2007
Revision K • 96154
PTP Addressing Scheme
The following terms and definitions apply to PTP operations:
Home Library: For two libraries connected by PTPs, the home library is the library 
supplying power and signals to the PTP through the left side of the Drive and 
Electronics Module, as viewed from the front of both libraries. 
Away Library: For two libraries connected by PTPs, the away library is the library on 
the left side of the home library as viewed from the front of both libraries.
The PTP addressing scheme is the same five-digit value as the other SL8500 devices and 
locations (see 
PTP numbering for the home library is:
Library number
Rail number (1-4 [internal firmware] or 0-3 [host])
-6 (Column number)
1 (Side number)
0 (Row number)
PTP numbering for the away library would be:
Library number
Rail (LSM) number (1-4 [hardware] or 0-3 [host])
+6 (Column number)
1 (Side number)
0 (Row number)
Note – 
Columns +6 and -6 are the PTP areas for a library. Column +6 in a library 
firmware address refers to libraries connected to the right, -6 indicates libraries 
connected to the left. 
However, the host software (ACSLS and HSC) consider Panel 1 as the PTP area, whereas 
elevators are Panel 0. The first library installed in the complex is 1 and each additional 
library added to the complex increments by 1. 
Home and away designations are always referenced from a PTP perspective of the 
library it is connected to. When more than two libraries are connected in a complex, 
every library that has two neighbors is both a home and away library, depending on the 
perspective of the PTP devices. For example, the middle library in a set of three is the 
home library for the PTP's on its left and the away library for the PTPs on its right. 
Configuring Library Partitions
Note – 
Library partitioning is a licensed feature which must be enabled by your Sun 
service representative. This feature is available starting with SL8500 firmware version 
3.7x and StreamLine Library Console version 3.25. See 